Dimensions, Table 1 – Hydrotech PURA QCRO Series Quick Change Reverse Osmosis Drinking Water System User Manual

Page 5

background image

3

19.8"

9.2"

Product Water Storage tanks

15.8”

2.0”

4.7”

14.3”

2.5”

13.1”

Dimensions

13.7"

13.7"

Notes
1. A booster is strongly recommended to improve the reduction of

TDS. Higher pressures will help maintain the membrane’s maximum
rejection performance.

2. The reverse osmosis membrane used in these systems may be

damaged by chlorine. These systems include activated carbon filters
which protect the membranes by reducing chlorine. Influent chlorine
should not exceed 3 mg/L.

3. A softener is strongly recommended for water over 10 gpg hard.

Installing a system without a softener on water with hardness higher
than 10 gpg will reduce the life of the membrane.

4. Additional information on factors that affect RO performance can be

found in the “Performance & Technical Information” section.

table 1

Recommended influent Water Characteristic

Pressure

40 - 100 psi

Temperature

40 - 77 ºF

Total Dissolved Solids (TDS)1

0 - 2500 ppm (0 - 2500 mg/L)

pH

5 - 10

Chlorine2

0 - 3 ppm (0 - 3 mg/L)

Chloramine

0 - 3 ppm (0 - 3 mg/L)

Turbidity

0 - 10 NTU

Hardness3

0 - 10 gpg

Iron

0 - 1 ppm (0 - 1 mg/L)

Bacterial Quality

Potable

QCRO4V-50 system certified by WQA to NSF/ANSI 58 and

CSA B483.1 for the reduction of the following substances,

as verified and substantiated by test data: Arsenic V,

Barium, Cadmium, Chromium III and VI, Copper, Fluoride,

Lead, Radium 226/228, Selenium, TDS and Turbidity.