10

Verify Flow Control Location

The RO manifold comes attached with
the elbow fitting flow control. This flow
control is attached to the manifold by
quick disconnect fitting which allows it
to be easily changed. Verify it is properly
located in the outlet next to the

symbol.

install tank Shut-off Valve

Flow Restrictor

1. Apply teflon (PTFE) tape to threaded

fitting at top of tank. Wrap tape
around clockwise 3 to 6 times for a
good seal.

1. Attach Shutoff valve

2. Attach shut off valve.

2. Slide compression nut over end of

3/8” white tubing, place the insert
in the end of the tube. Connect
the white 3/8” tubing to tank using
the compression nut.

3. Connect white 3/8” tubing to tank.

1

1

2

2

3

Metal tank Figure 6a

Figure 5

3/8” White Tubing

Plastic tank Figure 6B

Storage tank Preparation

Note: Changing the air pressure will

alter the amount of water
stored in the tank. Increasing
the pressure will decrease
capacity while decreasing
pressure will increase
capacity.

WaRNiNg! Do not use the
tank ball valve to lift or carry
the tank.