beautypg.com

Model 3200 timer, Timer setting procedure, Page 6 – Hydrotech 2510 Econominder Service Manual User Manual

Page 6

background image

MODEL 3200 TIMER

timer setting procedure

Page 6

IMPORTANT!

SALT LEVEL MUST ALWAYS BE ABOVE WATER LEVEL IN BRINE TANK.

How To Set Days On Which Water
Conditioner Is To Regenerate:

Rotate the skipper wheel until the number “1” is at the red
pointer. Set the days that regeneration is to occur by sliding
tabs on the skipper wheel outward to expose trip fingers.
Each tab is one day. Finger at red pointer is tonight. Moving
clockwise from the red pointer, extend or retract fingers to
obtain the desired regeneration schedule.

How To Set The Time Of Day:

Press and hold the red button in to disengage the drive gear.

Turn the large gear until the actual time of day is at the time
of day pointer.

Release the red button to again engage the drive gear.

How To Manually Regenerate Your Water
Conditioner At Any Time:

Turn the manual regeneration knob clockwise.

This slight movement of the manual regeneration knob
engages the program wheel and starts the regeneration
program.

The black center knob will make one revolution in the
following approximately three hours and stop in the position
shown in the drawing.

Even thought it takes three hours for this center knob to
complete one revolution, the regeneration cycle of your unit
might be set only one half of this time.

In any event, conditioned water may be drawn after rinse
water stops flowing from the water conditioner drain line.

How to Adjust Regeneration Time:

1.

Disconnect the power source.

2.

Locate the three screws behind the manual regeneration
knob by pushing the red button in and rotating the 24
hour dial until each screw appears in the cut out portion
of the manual regeneration knob.

3.

Loosen each screw slightly to release the pressure on
the time plate from the 24 hour gear.

4.

Locate the regeneration time pointer on the inside of the
24 hour dial in the cut out.

5.

Turn the time plate so the desired regeneration time
aligns next to the raised arrow.

6.

Push the red button in and rotate the 24 hour dial.
Tighten each of the three screws.

7.

Push the red button and locate the pointer one more
time to ensure the desired regeneration time is correct.

8.

Reset the time of day and restore power to the unit.

3200 ADJUSTABLE REGENERATION TIMER

SERVICE
POSITION
INDICATOR

24 HR. GEAR

MANUAL REGENERATION KNOB

RED TIME
SET BUTTON

SKIPPER WHEEL, 12 DAY
(SHOWS EVERY OTHER
DAY REGENERATION)

model
3210
remote
meter
timer

Delayed
Regen-
eration
Timer
Assem-
bly
(contin-
ued)

This manual is related to the following products: