GENERAL SERVICE HINTS
FOR METER CONTROL
Problem: Softener Delivers Hard Water
Cause could be that . . . Reserve capacity has been exceeded.
Correction: Check salt dosage requirements and reset program wheel to provide additional reserve.
Cause could be that . . . Program wheel is not rotating with meter output.
Correction: Pull cable out of meter cover and rotate manually. Program wheel must move without binding and clutch
must give positive “clicks” when program wheel strikes regeneration stop. If it does not, replace timer.
Cause could be that . . . Meter is not measuring flow.
Correction: Check output by observing rotation of small gear on front of timer (Note - program wheel must not be
against regeneration stop for this check). Each tooth to tooth is approximately 30 gallons. If not preforming properly,
replace meter.
7.
Excessive Water in Brine Tank
(continued)
C.
Timer Not Cycling.
C.
Replace timer.
D.
Foreign Material in Brine Valve.
D.
Replace Brine Valve Seat and Clean
Valve.
E.
Foreign Material in Brine Line Flow
Control.
E.
Clean Brine Line Flow Control.
8.
Softener Fails to Draw brine.
A.
Drain Line Flow Control is Plugged.
A.
Clean Drain Line Flow Control.
B.
Injector is Plugged.
B.
Clean Injector.
C.
Injector Screen Plugged.
C.
Clean Screen.
D.
Line Pressure is too Low.
D.
Increase Line Pressure to 20 P.S.I.
E.
Internal Control Leak.
E.
Change Seals, Spacers and Piston
Assembly.
9.
Control Cycles Continuously.
A.
Broken or Shorted Switch.
A.
Determine if Switch or Timer is Faulty
and Replace it, or Replace Complete
Power Head.
10. Drain Flows Continuously.
A.
Valve is not Programing Correctly.
A.
Check Timer Program and Positioning
of Control.
Replace Power Head Assembly if not
Positioning Properly.
B.
Foreign Material in Control.
B.
Remove Power Head Assembly and
Inspect Bore. Remove Foreign Mate-
rial and Check Control in Various
Regeneration Positions.
C.
Internal Control Leak.
C.
Replace Seals and Piston Assembly.
PROBLEM
CAUSE
CORRECTION