5600 models – Hydrotech 2510 Valve Automatic Water Filters: Activated Carbon, Turbidity (Multi-Media), Neutralizing User Manual
Page 7
5600 MODELS
Setting the 24 Hour Timer
This is a 24 hour timer and must correspond with the correct time of day on your wristwatch to ensure proper cycling of your filter.
•
Disengage the drive gear by pressing and holding in the red button on the left side of the control.
•
Now turn the large dial until the actual time of day is at the time of day arrow at the bottom of the panel.
•
Release the red button to reengage the drive gear.
•
The correct time of day on the 24 hour clock has now been set (a = am, p = pm)
Manual Regeneration Cycle
If you run out of filtered water because of inadequate regeneration frequency, power failure or unusually high water usage, you can
initiate a manual regeneration simply by turning the large knob on the front of the control clockwise until water starts running to drain.
The unit will now automatically complete a regeneration cycle and return to service.
Time of Automatic Regeneration
The time of automatic regeneration is factory set at 11:00 a.m.
5
MANUAL BACKWASH
KNOB
RED TIME
SET BUTTON
24 HR GEAR
RED POINTER
TIME OF DAY ARROW
SKIPPER WHEEL
SHOWS EVERY
OTHER DAY
BACKWASH