Setting the 24 Hour Timer

Press and hold the red button in to disengage the drive gear. Turn the
large dial until the actual time of day is opposite the time of day pointer.
Release the red button to re-engage the drive gear.

Determining the Backwash Frequency

The table on the following page can be used to help determine the
frequency of regeneration for MM and AC filters. Use this table as a guide -
individual circumstances will require more or less frequent regenerations.

To set a neutralizing filter (NE), follow the table under mild conditions.

NOTE: Add one person if you have a dishwasher.

No. of

Calendar Clock Regeneration Frequency - Number of Tabs Pushed outward

People

MILD

AVERAGE

EXTREME

2

1

1

1

1

1

2

2

2

2

2

3

3

3

3

3

3

3

1

1

2

2

3

3

3

3

3

3

4

4

4

4

4

4

4

1

2

2

2

3

3

3

4

4

4

6

6

6

6

6

6

5

2

2

3

3

4

4

4

4

5

5

5

5

12

12

12

12

6

2

2

3

3

4

4

4

6

6

6

6

12

12

12

12

12

7

2

3

3

4

4

6

6

6

12

12

12

12

12

12

12

12

8

2

3

3

4

6

6

6

6

12

12

12

12

12

12

12

12

9

3

3

4

4

6

6

12

12

12

12

12

12

12

12

12

12

10

3

4

4

6

6

12

12

12

12

12

12

12

12

12

12

12

Setting the Backwash Frequency

The filter control features a skipper wheel with twelve numbered tabs and trip fingers, each representing one day of a twelve day
schedule. By adjusting the skipper wheel tabs, the control can be programmed to backwash every second third, fourth, sixth or twelfth
day, according to your requirements. The control is shipped with the skipper wheel tabs pushed outward. You must push the tabs in
toward the center of the wheel (retracting the trip finger) for each day that backwashing is not required.

Rotate the skipper wheel until number “1” is at the pointer. Leave this tab out. Moving clockwise around the skipper wheel, adjust the
remaining tabs using the following table as a guide.

Manual Regeneration

Turn the manual regeneration knob clockwise. This slight movement of the manual regeneration knob engages the program wheel and
starts the regeneration program. The back center knob will make one revolution in approximately three hours and stop in the position
shown in the drawing. Actual backwash time is 14 minutes. In any event, treated water may be drawn after rinse water stops flowing
from the filter’s drain line.

Backwashes

Skipper Wheel Tab Settings

Needed

in 12 days

1

2

3

4

5

6

7

8

9

10

11

12

1

Out

In

In

In

In

In

In

In

In

In

In

In

2

Out

In

In

In

In

In

In

In

In

In

In

In

3

Out

In

In

In

Out

In

In

In

Out

In

In

In

4

Out

In

In

Out

In

In

Out

In

In

Out

In

In

6

Out

In

Out

In

Out

In

Out

In

Out

In

Out

In

12

Out

Out

Out

Out

Out

Out

Out

Out

Out

Out

Out

Out

Programming Backwash Controls

MANUAL
BACKWASH KNOB

RED TIME SET
BUTTON

24 HOUR
CLOCK
DIAL

SERVICE
POSITION
INDICATOR
DOT

RED
POINTER

TAB

TRIP
FINGER

SKIPPER WHEEL
SHOWS EVERY OTHER
DAY BACKWASH