Installation and start-up procedure, Typical installations, Installation instructions – Hydrotech 2510 Valve Automatic Water Filters: Activated Carbon, Turbidity (Multi-Media), Neutralizing User Manual
Page 4
2
NOTE: A neutralizing filter is the first
unit installed in a water system after
the outdoor raw water lines (*)
when pH correction is required.
RAW WATER
OUTDOOR
FILTERED
WATER
RAW FILTERED
WATER
SOFTENER
SOFTENER
TASTE & ODOR FILTER
TASTE & ODOR FILTER
TURBIDITY FILTER
PRESSURE
TANK
SOFT
WATER
DRAIN
DRAIN
DRAIN
DRAIN
DRAIN
RAW WELL
WATER
IN
OUT
IN
OUT
IN
OUT
IN
OUT
IN
OUT
RAW WATER
OUTDOOR
RAW WELL
WATER
PRESSURE
TANK
RETENTION
TANK
CHLORINATOR
CHECK VALVE
FLOW SWITCH
SOFT
WATER
Installation Instructions
CAUTION: If the ground from the electrical panel or breaker box to
the water meter or underground copper pipe is tied to the copper
water lines and these lines are cut during installation of the Noryl
bypass valve and/or poly pipe, an approved grounding strap must
be used between the two lines that have been cut in order to
maintain continuity. The length of the grounding strap will depend
upon the number of units being installed and/or the amount of
copper pipe being replaced with poly. See Figure 1.
In all cases where metal pipe was originally used and is later
interrupted by poly pipe or the Noryl bypass valve, as in Figure 1,
or by physical separation, as in Figure 2, to maintain proper
metallic pipe bonding, an approved ground clamp c/w not less than
#6 copper conductor must be used for continuity.
Check your local electrical code for the correct clamp and cable
size.
NOTE: This timer’s programs will be out of sync if you turn the
knob too far or do not allow the drive motor to stop completely
before continuing to the next step. If this happens while doing any
procedure, rotate the knob clockwise until the white dot lines up
with the time of day arrow and the unit will return to the service
position. You can then start again.
1.
Place filter on a flat surface in desired location, near a drain and 115 volt AC outlet. Subjecting your filter to freezing or to water
temperatures above 120°F (49°C) will void the warranty. Remove the valve from the carton. Be sure the distributor tube is in
place. Carefully position the valve over it and turn securely on to the fiberglass tank.
All multimedia and some larger units are supplied with the media packaged separately. Please refer to Page 7 - Installation and
Replacement of Filter Media Pak.
Installation and Start-up Procedure
Ground
From
Panel
Electrical Panel
Ground Strap
Copper Pipe
Water Meter
Softener
c/w Plastic Bypass
Poly Pipe
Poly Pipe
Figure 1
Hard Water Bypass
Loop Cut & Capped
Hard Water Line for Outside & 3rd Tap Comes From Meter
Soft Water Line in Home
Figure 2
Typical Installations