background image

47

2. For Models With Johnson Controls Direct Spark Ignition (DSI) Module (G760)

Theory Of Operation:

Start the drying cycle. When the gas burner

ignites within the chosen trial for ignition time

(6-seconds), the flame sensor detects gas

burner flame and signals the DSI module to

keep the gas valve open...as long as there is

a call for heat. The DSI module will

“LOCKOUT” if the gas burner flame is not

sensed at the end of the trial for ignition

period. The trial for ignition period will be

repeated for a total of three (3) retries/trials

(the initial try and two [2] more retries/trials).

If the flame is not sensed at the end of the

third retry/trial (inter-purge period of

30-seconds) the DSI module will

“LOCKOUT” (light emitting diode [L.E.D.]

flashes).

A steady L.E.D. indicator indicates normal

operation.

No L.E.D. indicator indicates a power or an

internal failure has occurred.