Page 25: 21 b. electric models only
21
b. Electric Models Only
IMPORTANT: Figures shown are for non-reversing models only. For reversing models contact the
factory.
IMPORTANT: The dryer must be connected to the electric supply shown on the data label that is
affixed to the left side panel/wall area behind the control door. In the case of 208
VAC or 240 VAC, the supply voltage must match the electric service specifications
of the data label exactly.
IMPORTANT: The wire size must be properly sized to handle the related current.
WARNING: 208 VAC AND 240 VAC ARE NOT THE SAME. Any damage done to dryer
components due to improper voltage connections will automatically VOID THE
WARRANTY.
NOTE: ADC reserves the right to make changes in specifications at any time without notice or
obligation.
IMPORTANT: 3-phase (3ø) figures shown are for a 3-wire service only.
APPROX.
AMP
DRA
W
M LE-75 (E
LECTRIC
)
ELECTRICAL SERVICE SPECIFICATIONS (PER DRYER)
IMPORTANT: 208 VAC and 240 VAC ARE NOT THE SAME. When ordering, specify exact voltage.
NOTES:
A. Fuse ratings are dual element, time delay, current limiting, class RK1 or RK5 ONLY.
B. Circuit breakers are thermal/magnetic (industrial) motor curve type ONLY. For others, calculate/verify correct breaker size according to appliance amp draw
rating and type of breaker used.
C. Circuit breakers for 3-phase (3ø) dryers must be 3-pole type.
APPLIED VOLTAGE/PHASE
KW
208/1ø (60 Hz)
240/1ø (60 Hz)
208/3ø (60 Hz)
240/3ø (50/60 Hz)
380/3ø (50 Hz)
416/3ø (50 Hz)
460/3ø (60 Hz)
20
104
90
---
---
33
---
---
24
---
---
72
63
---
36
33
30
---
---
88
77
---
45
41
33
---
---
---
---
53
---
---
36
---
---
105
92
---
53
48
40
---
---
---
---
---
59
---