L. shut down instructions – American Dryer Corp. ML-75DIII User Manual
Page 43
39
1) Select drying time and cool down time desired...
a) Turn heat timer clockwise (CW) to the desired time (i.e., 1 minute to 60 minutes).
b) Turn cool down timer clockwise (CW) to the desired time (i.e., 0 minutes to 30 minutes).
2) Select drying temperature (HI TEMP, LO TEMP, or PERM PRESS).
3) Push Start button...
a) Dryer will now start.
4) To stop the dryer, open the main door.
L. SHUT DOWN INSTRUCTIONS
If the dryer is to be shutdown (taken out of service) for a period of time, the following must be performed:
1. Discontinue power to the dryer either at the external disconnect switch or the circuit breaker.
2. Discontinue the heat supply:
a. GAS MODELS ... discontinue the gas supply.
1) SHUT OFF external gas supply shutoff valve.
2) SHUT OFF internal gas supply shutoff valve located in the gas valve burner area.
b. STEAM MODELS ... discontinue the steam supply.
1) SHUT OFF external (location furnished) shutoff valve.
2) SHUT OFF internal steam valves in the supply lines and the return lines.