Alliance Laundry Systems Extractors P232156R9 User Manual
Page 12

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Basic Installation/Operation
F232156
10
Table 2 (continued)
UWAV Pocket Hardmount General Specifications
Specifications
35
60
80
100
125
Drive Train Information
Number of motors in drive train
1
1
1
1
1
Drive motor power, hp (kW)
2.3 (1.7)
2.9 (2.2)
5.0 (3.7)
5.0 (3.7)
7.5 (5.6)
Cylinder Speeds / Centrifugal Force Data
1/2 Wash/reverse, RPM / g
26 / .25
26 / .31
26 / .35
26 / .35
26 / .40
Wash/reverse, RPM / g
42 / .66
40 / .73
40 / .82
40 / .82
37 / .82
Distribution, RPM / g
83 / 2.57
71 / 2.29
73 / 2.57
70 / 2.50
62 / 2.29
High extract 1, RPM / g
329 / 40
297 / 40
280 / 40
280 / 40
260 / 40
High extract 2, RPM / g
534 / 106
483 / 106
456 / 106
456 / 106
422 / 106
High extract 3, RPM / g
656 / 160
594 / 160
560 / 160
560 / 160
518/ 160
Balance Detection
Vibration safety switch installed
N/A
STD
STD
STD
STD
Safety switch gap setting, in. (mm)*
N/A
.25 (.010) NO-GO
.20 (.008) GO
.25 (.010) NO-GO
.20 (.008) GO
.25 (.010) NO-GO
.20 (.008) GO
.20 (.008) NO-GO
.15 (.006) GO
Direct Steam Heating (Optional)
Steam inlet connection size, in. (mm)
.5 (13)
.5 (13)
.5 (13)
.5 (13)
.75 (19)
Number of steam inlets
1
1
1
1
1
Steam required to raise bath
temperature,
10°F, lb. (10°C, kg)
LOW
2.1 (1.5)
3.3 (2.4)
4.6 (3.3)
5.7 (4.1)
6.7 (4.9)
MED
2.3 (1.7)
3.7 (2.6)
5.2 (3.8)
6.5 (4.7)
7.8 (5.6)
HIGH
2.7 (1.9)
4.1 (2.9)
6.1 (4.4)
7.6 (5.5)
9.1 (6.6)
Average consumption per cycle, bhp
(kg)
1.4 (21.4)
2.1 (33.4)
3.1 (48.4)
3.8 (60.4)
4.6 (72.0)
Electrical Heating (Optional)
Total electrical heating capacity, kW
15.6
25.2
37.8
37.8
50.4
Number of electrical heating elements
6
6
9
9
12
Electrical heating element size, kW
2.6
4.2
4.2
4.2
4.2
Time required to raise bath
temperature,
10°F, min. (10°C, min.)
LOW
2.4 (3.6)
2.4 (3.7)
2.2 (3.4)
2.8 (4.2)
2.5 (3.8)
MED
2.7 (4.1)
2.7 (4.1)
2.5 (3.9)
3.2 (4.8)
2.9 (4.4)
HIGH
3.1 (4.7)
3.0 (4.6)
3.0 (4.5)
3.7 (5.6)
3.4 (5.1)
* Gap setting should be made with “GO/NO-GO” type feeler gauge.
Table 2