Replacement parts list – APW Wyott CMW-24 User Manual
Page 8
![background image](/manuals/33169/8/background.png)
8
NOTICE
TROUBLESHOOTING
IF THE UNIT BLOWSAFUSE OR TRIPSACIRCUIT BREAKER
IF THE HEATERS DO NOT LIGHT
IF THE COOLING FAN DOES NOT RUN
Service work should be preformed only by a qualified technician who is experienced in and
knowledgeable with the operation of commercial gas, electric, steam cooking equipment. Contact the
Authorized Service Agency for reliable service, dependable advise or other assistance and for genuine
factory parts.
Warranty will be void and the manufacturer is relieved of all liability if:
(A) Service work is performed by other than anAPW WyottAuthorized ServiceAgency or
(B) Other than GenuineAPW Wyott replacement parts are installed.
A current listing of all authorized APW Wyott authorized parts/service distributors is included with this
product manual at the time of shipment. In the absence of this list you call the APW Wyott 24 hour Service
Hot Line which gives access to the nearest Authorized APW Wyott parts/service distributor. Call 1-800-
733-2203.
1.
Check the capacity of the circuit to insure that it is not overloaded, as the oven should have its own
branch circuit.
2.
Short circuits may be accompanied by sputtering sounds or sparks.
1.
If the pilot light does not come on and the cooling fan does not run, check for a blown fuse or an open
circuit breaker.
2.
Check for failure of the main switch.
3.
If the pilot light is lit and the cooling fan is running but the heaters do not light, call an authorized
service representative.
Remember, when the unit is operating in standby, with no product on the rack, the heaters may not
glow, but will still emit some heat.
4.
If one heater is lit, but the other is not, a burnout or loose connection is probable cause. Check that
heater is properly seated in its socket, then consult an authorized service representative.
1.
If the pilot light is not lit and the heaters do not light, see items 1,2,3 above.
2.
If the pilot light is lit and the heaters function, consult an authorized service representative.
IF THE HEATERS DO NOT COME UP TO FULL HEAT WHEN THE PRODUCT IS PLACED ON THE RACK
1.
Be sure that product is on the front half of the rack. The rack is ba uced to trip the actuating switch,
but the weight must be on the front half of the rack to insure that it does so.
2.
Check that the rack is at the same level on both sides, and is correctly inserted.
3.
If the rack operates freely and the heater still does not function properly, contact an authorized
service representative.
Item Part No.
.
Description
Quan Item Part No.
.
Description
Quan
REPLACEMENT PARTS LIST
1
2
3
4
5
6
7
8
9
10
1
1
1
1
1
*
*
*
1
1
1
1
4
4
4
4
2
2
2
2
11072-03
12154-00
11372-02
13016-09
13016-13
13016-06
15208-00
31008-01
11195-22
31007-56
Terminal block
Cooling fan
Voltage regulator
Rack switch, 24" & 36" models
Rack switch, 48" models
Main power switch
Pilot light
Heater socket
Contactor
Wire rack, 48" models
11
12
13
14
15
16
17
18
19
20
31007-80
31007-55
825301-00
825301-50
825300-00
825300-50
825332-00
825331-00
825538-00
825536-00
Wire rack, 36" models
Wire rack, 24" models
Heater, 240V, 48" models
Heater, 240V, 48" Canadian models
Heater, 208V, 48" models
Heater, 208V, 48" Canadian models
Heater, 240V, 36" models
Heater, 208V, 36" models
Heater, 240V, 24" models
Heater, 208V, 24" models
*Number required varies with unit.