beautypg.com

Attention installer – Hellwig Air 6015 User Manual

Page 8

background image

559-734-7451 800-367-5480 FAX 559-734-7460

16. Complete passenger and driver’s side installation of air spring assembly.

17.Select a location for the air inflation valves. The location can be on the

bumper or body of the vehicle where an air chuck can be used to inflate the air
springs. Select a location where the valve will not be damaged or interfere
with the operation of other components.

18.Cut air brake lines to length and connect air lines to fittings by pushing the air

line into the air fittings as far as possible.

WHEN CUTTING AIR BRAKE

TUBING, A SQUARE CUT IS REQUIRED AND THE HOSE END

MUST NOT BE DEFORMED OR LEAKAGE MAY RESULT. IF DE-

FORMATION OF THE HOSE END OCCURS, THE HOSE END MUST

BE REWORKED SO THAT IT IS ROUND. Engagement of the sealing
O-ring will be felt when the air line has been inserted properly into the fitting.
Fittings may be disconnected if required by pushing down on the outer ring
while pulling firmly on the air line. Route air lines away from exhaust pipes
or any other sources of heat and ensure that the air lines are protected from
sharp edges. A length of heat shielding is provided to protect the air line as it
exits the passenger side air spring.

19.Inflate air springs to 40 psi and check for leaks. A soapy water solution can be

used to find slow leaks.

20.When satisfied with integrity of the system, adjust air pressure to desired level.

The air springs can be inflated to any level between 10 and 60 psi. DO NOT
EXCEED THE GVW RATING OF THE VEHICLE. DO NOT run the air
springs empty or warranty will be void. MINIMUM air spring pressure is 5
psi. Failure to keep air in the air springs will void the warranty.

For best

RIDE use only enough air pressure as required to level the vehicle. If a firmer
ride is desired, more pressure can be used.

21.Check air pressure in the system regularly to ensure system performance and

maintenance of warranty. Just like tires, the air pressure in the system will
vary due to temperature changes. For your air spring system to function prop-
erly it must be checked on a regular basis.

ATTENTION INSTALLER

: BE SURE THAT THE CUSTOMER

RECEIVES THIS INSTRUCTION SHEET, ALL IMORTANT NOTE

CARDS AND THE WARRANTY FORM.

6012 ( R-6012 )

12/06/06

This manual is related to the following products: