beautypg.com

Gardner Bender B2000 Series E Cyclone Bender User Manual

Instruction sheet, Gardner bender, B2000 cyclone

background image

Gardner

Bender

IMPORTANT RECEIVING INSTRUCTIONS:

Visually inspect all components for shipping damage. If any shipping

damage is found, notify carrier at once. Shipping damage is NOT covered by warranty. The carrier is responsible for
all repair or replacement costs resulting from damage in shipment.

Instruction

Sheet

B2000

Cyclone

®

Bender

Serial Numbers Begining With “E”

IMPORTANT USER SAFETY AND PROTECTION: In setting up systems to fit your operations, care must be taken
to select the proper components and design to insure appropriate integration with your operations and existing
equipment and that all safety measures have been taken to avoid the risk of personal injury and property damage
from your application or system.

Upper Roller

High/Low

Voltage

Indicator

Bending

Shoe

Frame

Stop

Pendant Control

GB ELECTRICAL CANNOT BE RESPONSIBLE FOR DAMAGE OR INJURY CAUSED BY UNSAFE USE,
MAINTENANCE OR APPLICATION OF ITS PRODUCTS.
Please contact GB Electrical for guidance when you are
in doubt as to the proper safety precautions to be taken in designing and setting up your particular application.

Description

The Cyclone

®

, GB model B2000 production bender is

used to bend EMT, IMC, rigid steel or rigid aluminum
conduit. A single bending shoe accommodates sizes

1

2

",

3

4

", 1", 1

1

4

", 1

1

2

" and 2" conduit. The shoe is

driven by a 115 volt, 15 amp motor. The roller housing
consists of a single urethane roller and support arm,
also three sets of nylon rollers.

The bender control pendant consists of a zero light, an
override push button and a two-position toggle switch
for “Bend and Return”.

An 8-ft electrical cord connects the pendant to the
bender frame.

The bender can be used in a horizontal or
vertical position.

To avoid damaging the bender control circuit, an input
voltage sensing system is built into the control circuit. If
input voltage is less than 92V AC or higher than
132V AC the bender will shut off. One of the two lights
located on the end plate will light to indicate whether
high or low voltage exists.

Re-set the bender by unplugging the power cord, and
plugging it in again. If the incoming current voltage has
not been corrected, the bender will continue to shut off.
The voltage range must be within 92V AC to 132V AC.
Any situation which causes a voltage drop or increase
must be corrected before using the B2000 Bender.

Voltage drops may be caused by:
• Extension cords that are too long.
• Extension cords made of light (16-18 gauge) wire.
• Multiple power tools on a single circuit.
• Other devices which require high amperes to operate.

Specifications

Power Source.............................120V 60 cycle AC
Pendant Control Circuit ..............12V DC
Motor ..........................................1 h.p. 100V 60 cycle DC
Weight ........................................345 lbs.
Height .........................................38 inches
Width ..........................................31 inches
Length ........................................45 inches
Fuses, Time Delay .....................15 Amp
Bend Capability ..........................

1

2

" - 2" IMC, EMT

Rigid Steel or Rigid
Aluminum

RPS-0097 3/27/00 1:03 PM Page 1