6 technical data, 1 operating conditions 6.2 general technical data, 6technical data – Burkert Type 7615 User Manual
Page 8
8
Technicaldata
6
TECHNICAL DATA
6.1
Operating conditions
WARNING!
Burns, chemical burns through leaking medium.
▶ Prior to the use of aggressive media, the resistance of the
media-wetted parts must be checked.
You can access the Bürkert Chemical Resistance Chart on the
Documentation Brochures
Chemical Resistance Chart. If you are unsure, please contact your
Bürkert Sales Center.
NOTE!
Malfunction!
▶ Do not use Type 7615 outdoors without the appropriate hous-
ing and avoid heat sources that may cause the permissible
temperature range to be exceeded.
Permitted temperatures
Ambient temperature: +10 to +55°C
Medium temperature: +15 to +60°C (FFKM seals)
+ 5 to +60°C (EPDM seals)
Media: Neutral and aggressive liquid media. Check suitability
according to the Chemical Resistance Chart.
Protection class: IP40
6.2
General technical data
Observe the technical specifications as detailed on the type
plate!
Max. manometric pressure: approx. 1 bar (overpressure towards
the atmospheric pressure)
Dosing quantity:
5 µl/stroke
Connections:
4-pole Molex connector
(Molex no. 50-57-9404)
6.2.1 Rating plate
Example:
Housing material
Seal material
Voltage / type of current
Power
Device designation
Serial number
Date of manufacture
(encoded)
Identification number of
the device
7615 CC PK
Made in Germany
00202784
W16LP
DOSING UNIT
24V DC
11W
S/N 1050
Type
Fig. 1: Rating plate description
english
Type 7615