beautypg.com

6 technical data, 1 operating conditions 6.2 general technical data, 6technical data – Burkert Type 7615 User Manual

Page 8

background image

8

Technicaldata

6

TECHNICAL DATA

6.1

Operating conditions

WARNING!

Burns, chemical burns through leaking medium.

▶ Prior to the use of aggressive media, the resistance of the

media-wetted parts must be checked.

You can access the Bürkert Chemical Resistance Chart on the
Internet at

www.buerkert.de

Documentation Brochures

Chemical Resistance Chart. If you are unsure, please contact your
Bürkert Sales Center.

NOTE!

Malfunction!

▶ Do not use Type 7615 outdoors without the appropriate hous-

ing and avoid heat sources that may cause the permissible

temperature range to be exceeded.

Permitted temperatures

Ambient temperature: +10 to +55°C

Medium temperature: +15 to +60°C (FFKM seals)

+ 5 to +60°C (EPDM seals)

Media: Neutral and aggressive liquid media. Check suitability

according to the Chemical Resistance Chart.

Protection class: IP40

6.2

General technical data

Observe the technical specifications as detailed on the type
plate!

Max. manometric pressure: approx. 1 bar (overpressure towards

the atmospheric pressure)

Dosing quantity:

5 µl/stroke

Connections:

4-pole Molex connector

(Molex no. 50-57-9404)

6.2.1 Rating plate

Example:

Housing material

Seal material

Voltage / type of current

Power

Device designation
Serial number

Date of manufacture
(encoded)

Identification number of
the device

7615 CC PK

Made in Germany

00202784

W16LP

DOSING UNIT

24V DC

11W

S/N 1050

Type

Fig. 1: Rating plate description

english

Type 7615