Section 2 Installation

Installation and Operation Manual
X-VA-GT1000-eng
Part Number: 541B078AAG
March, 2014

Model GT1000 Series

B. Piping Arrangement

It is strongly recommended that the typical piping arrangement shown in

Figure 2-1, be used when installing the meter. This piping arrangement
permits the meter to be isolated from the flow for servicing or cleaning.
The design of the GT1000 flowmeter allows the horizontal inlet and outlet
end fitting to rotate independently of each other simply by loosening the
two clamp bolts for each end fitting at the rear of the meter. Additionally
the various end fittings offer horizontal or vertical connections or a
combination of both.

Figure 2-1 Typical Flowmeter Piping Configuration

A - Inlet Valve

B - Outlet Valve

C - Bypass Valve

D - Control Valve

E - Drain Valve

HORIZONTAL

LINE

D

A

E

C

VERTICAL

LINE

B

B

A

E

FLOWMETER

C

D

FLOWMETER