Flowline LI90 Commander User Manual
Page 44

44 of 57
PRELIMINARY MANUAL
27 AUG 08
Commander LI90 Series
Rev 1_3
o
Vertical Tanks – Select among Rectangular, Round Bottom or Cone Bottom.
Rectangular
Round Bottom
Cone Bottom
1. Sensor Height
2. Tank Height
3. Tank Width/Diameter
4. Tank Length/Cone
• Sensor Height – This is the distance from the bottom of the tank to the
bottom of the sensor
• Tank Height – This is a dimension for either the Height of the Tank or
the Height of the Straight Side of the cone bottom tank.
• Tank Width / Diameter – This is either the width of the tank or the
diameter of the tank
• Tank Length / Cone – This is either the length of the tank or the Height
of the Cone. You do not need to configure this setting for the Round
Bottom tank.
• Use the Next soft key to advance to the next setting
• Use the Back soft key to return to the previous setting