Installation & operation continued, Ts06a with scl, to emr – Fill-Rite TS06 LPG Precision Meter User Manual
Page 6
Where the TS06A is used in a commercial or retail LPG dis-
penser, the flow meter will be shown in dispenser manufac-
turer wiring diagram.
When the TS06A-EDM is used as a free-standing dispenser
meter, it can be used with many different electronic regis-
ters, which can be either installed on the flow meter, or re-
mote.
In wiring diagrams on these 2 pages, we show the flow me-
ter used with registers available through Tuthill. it can of
course also be used with many other registers.
6
Installation & Operation continued
#1
EL0300-5-?
#6
#2 & #3
#5
#4
EMR³ ground
1.
The SCL is
model specific, and in some cases also application specific.
Do NOT transfer to another flow
meter without consulting with Tuthill.
2. Use 4 conductor shielded cable.
3. Terminate shields at receiving instrument (register).
4. Move W1 shunt (jumper) to match operating voltage:
5. S1 must be in Q position.
6. Output signal has an internal pull-up resistor (1000 Ω ) on each channel.
7. If the receiving instrument (register) is more than 200’ (60 m) cable distance from the flow meter, an amplifier is
required on the pulse signal. If this option was not ordered, please consult with Tuthill prior to start-up.
1 pin exposed: 5.5 - 12 VDC
= EL0300-5-1
Both pins covered: 5VDC Regulated
= EL0300-5-3
TS06A with SCL, to EMR³