Trouble shooting – Fill-Rite TS06 LPG Precision Meter User Manual

Page 17

background image

Problem

Leakage from seal cover.

Product flows through meter but the regis-
ter does not operate

Breaking teeth on gears.

No flow or low flow through the meter

Meter operates too slowly:

Product flows through the meter but regis-
ter does not record properly:

Probable Cause and Solution



Seal has been damaged due to shock



Cover bolts have not bee tightened sufficiently



Replace seal and /or re-torque bolts




Pulser is not functioning properly



Meter gears are jammed and not turning



Replace the pulser, inspect internal meter parts




Starting or stopping flow too rapidly.



Normal wear after long service



Replace gears



Correct system operation



Check pump by-pass setting.




Faulty non-functioning pump



Differential vale not open or not functioning. Replace valve



Meter “frozen” due to build up of salts or frozen material. Clean meter
internals and inspect for damage



Vapor vent line valve shut or obstruction in vapor vent line. Open valve
or remove obstruction



Strainer dirty and plugged. Clean Strainer



U-Cups on differential valve leaking. Replace U-Cups



Differential valve internal mechanism faulty. Valve does not open fully.



Meter gears or rotors partially “salted”, enough to slow the rotating
gears. To correct, clean gears.



Strainer partially plugged. Clean strainer basket.



Pump not functioning properly. Repair pump





Pulse output board faulty, or not calibrated for electronic register.



Vapor release valve sticking.



Differential valve leaking.



Repair or replace as necessary.

17

Trouble Shooting