Fluid compatibility, Safety testing approvals – Sotera SV Series User Manual
Page 12

12
SV Pump & Motor Performance
Pressure ~ 20 PSI (2.07 bar) bypass valve setting (up to 40 cps viscosity)
20 GPM (75 LPM) for the following models:
o SV20A1DBSB
o SV20A1DNSD
o SV20A2DBSD
o FRSA120800MN
o FRSA120800N
o FRSA120801MA
TDH = 46 feet at bypass valve rating
Operating temperature 14º – 104ºF* (4º C - 49º C)
Overall Dimensions:
AC DEF Pump: 6” wide X 6” high x 12” deep.
DC DEF Pump: 14.15” wide X 16.6” high x 14” deep.
Shipping Weight:
AC DEF Pump: 25 lbs.
DC DEF Pump: 25 lbs.
Fluid Compatibility
Diesel Exhaust Fluid (Aqua Urea 32.5% solution) Diesel Fuel Mineral Spirits
Stoddard Solvents
Safety Testing Approvals
The motors used in the
Sotera line of pumps have been safety tested for compliance to
the standards set forth by UL Laboratories.
This product complies with European Directive: 2006/42/EC Machinery and 2011/65/EU
Hazardous Substances.
The following harmonized standards were applied: EN ISO 12100:2010 Safety of
Machinery, EN 809:1998 +A1:2009 Pumps for Liquids
IMPORTANT! If in doubt about compatibility of a specific fluid, contact supplier of
fluid to check for any adverse reactions to the following wetted materials:
Stainless Steel Fluorocarbon
Acetal
WARNING! This pump is not for use with fluids that have a flash point below 100°F
(37.8°C, i.e.: gasoline, alcohol). Refer to NFPA 325M (Fire Hazard Properties of
Flammable Liquids, Gases, and Volatile Solids) for flash points of common liquids.
Static electricity buildup and discharge could result in arc and explosion.
DC000568-000 Rev 1
•
•
•
•
o FRSD120800MN
o FRSD120800N
o FRSD120801MA