beautypg.com

Fluid compatibility, Safety testing approvals – Sotera SV Series User Manual

Page 12

background image

12

SV Pump & Motor Performance

Pressure ~ 20 PSI (2.07 bar) bypass valve setting (up to 40 cps viscosity)

20 GPM (75 LPM) for the following models:

o SV20A1DBSB

o SV20A1DNSD

o SV20A2DBSD

o FRSA120800MN

o FRSA120800N

o FRSA120801MA

TDH = 46 feet at bypass valve rating

Operating temperature 14º – 104ºF* (4º C - 49º C)

Overall Dimensions:

AC DEF Pump: 6” wide X 6” high x 12” deep.

DC DEF Pump: 14.15” wide X 16.6” high x 14” deep.

Shipping Weight:

AC DEF Pump: 25 lbs.

DC DEF Pump: 25 lbs.

Fluid Compatibility

Diesel Exhaust Fluid (Aqua Urea 32.5% solution) Diesel Fuel Mineral Spirits

Stoddard Solvents

Safety Testing Approvals

The motors used in the

Sotera line of pumps have been safety tested for compliance to

the standards set forth by UL Laboratories.

This product complies with European Directive: 2006/42/EC Machinery and 2011/65/EU

Hazardous Substances.

The following harmonized standards were applied: EN ISO 12100:2010 Safety of

Machinery, EN 809:1998 +A1:2009 Pumps for Liquids

IMPORTANT! If in doubt about compatibility of a specific fluid, contact supplier of

fluid to check for any adverse reactions to the following wetted materials:

Stainless Steel Fluorocarbon

Acetal

WARNING! This pump is not for use with fluids that have a flash point below 100°F

(37.8°C, i.e.: gasoline, alcohol). Refer to NFPA 325M (Fire Hazard Properties of

Flammable Liquids, Gases, and Volatile Solids) for flash points of common liquids.

Static electricity buildup and discharge could result in arc and explosion.

DC000568-000 Rev 1

o FRSD120800MN

o FRSD120800N

o FRSD120801MA