Setting the thermostatic mixing valve, Starting and stopping the control system, 4 starting and stopping the control system – DE DIETRICH BSL 200...400 - BESL 200...400 User Manual
Page 17

4.3.2.
Setting the thermostatic mixing valve
28
Domestic cold water inlet
57
Domestic hot water outlet
The mixing valve is set in the factory for a DHW outlet temperature of
60°C (position 6). To lower this temperature, remove the top cover
and turn the wheel anti-clockwise. In position 1, the outlet temperature
is lowered to 35°C.
Position
1
2
3
4
5
6
Temperature at the mixer valve outlet 35 °C 40 °C 45 °C 50 °C 55 °C 60 °C
4.4
Starting and stopping the control system
CAUTION
If the temperature in the solar collectors is higher than
130°C, the control system operates in safety mode. Wait
until the evening before start-up or cool down (cover) the
solar collectors.
Commissioning is performed by the installer. Once connected to the
power supply, the control system is in automatic mode. To initiate the
solar pump, a minimum temperature of 30 °C is required at the
collector and a temperature difference of 6 °C with respect to the
domestic hot water calorifier.
If the particular conditions make it necessary to adjust the
settings, contact the installer.
C003732-A
57
28
BSL 150...400 BESL 200...400
4. Operating the appliance
14/10/2013 - 300028413-001-02