beautypg.com

User settings, Setting the time, Force back-up – DE DIETRICH BSL 200...400 - BESL 200...400 User Manual

Page 15: Modifying the back-up authorisations, In the event of prolonged absences, 2 user settings

background image

4.2

User settings

4.2.1.

Setting the time

1. Select the HRE channel with the ( and ) keys.
2. Press the B key for 2 seconds.
3. Set the hour with the ( and ) keys.
4. Press the B key to confirm.
5. Set the minutes with the ( and ) keys.
6. Press the B key to confirm.

CAUTION

The controller does not switch between summer and

winter time.

4.2.2.

Force back-up

1. Select the RAP channel with the ( and ) keys.
2. Press the B key for 2 seconds. The symbol T flashes.
3. Set the RAP parameter to ON using the ) key.
4. Press the B key to confirm the setting.

The electrical back-up shuts down when the set point

temperature is attained.

4.2.3.

Modifying the back-up authorisations

Throw the switch to modify the electrical back-up authorisations.

E

Winter: Electrical back-up is authorised day and night.

0 Electrical back-up is not authorised. No back-up heating.
Z

Summer: Electrical back-up is only authorised at night.

The back-up is deactivated if the solar pump is running.

4.2.4.

In the event of prolonged absences

In the event of prolonged absence, shut down the electrical back-up

if the function is activated and reduce the setpoint of the solar DHW

tank:

M002763-A

BSL 150...400 BESL 200...400

4. Operating the appliance

14/10/2013 - 300028413-001-02

14