Operating the appliance, Reading out measured values, Resetting the values to zero – DE DIETRICH BSL 200...400 - BESL 200...400 User Manual
Page 14: 4 operating the appliance, 1 reading out measured values
4 Operating the appliance
4.1
Reading out measured values
Scroll down the values measured using the ( and ) keys.
Parameter Description
Remarks
TC
Collector temperature S1 sensor.
The value TC shows the temperature in °C given by the collector sensor in real time.
TR
Calorifier temperature
(Solar exchanger -
lower)
S2 sensor.
The value TR shows the temperature in °C in real time measured by the sensor in the lower
zone of the DHW calorifier.
THR
Calorifier temperature
(Back-up)
S3 sensor.
The value THR shows the temperature in °C in real time measured by the sensor in the
upper zone of the DHW tank.
PC %
Pump regime
Value PC % gives the solar heating pump regime in real time (0-100%).
tc
Auto-calibration time
The value tc shows the self-calibration phase time remaining in seconds.
RAP
Force back-up
On
: Back-up powered up.
AUTO
: Back-up managed by the control system.
¼See chapter: "Force back-up", page 14.
h P1
Hour run meter on the
solar pump
Reset to zero possible.
¼See chapter: "Resetting the values to zero", page 13.
KWh
Amount of heat (kWh) 4
The amount of heat received is calculated according to the parameters input on
commissioning (DMAX).
4
Reset to zero possible.
¼See chapter: "Resetting the values to zero", page 13.
Values KWh or MWh give an estimate of the total amount of heat produced by the
installation in kWh or MWh since commissioning of the control system. The amount of heat
received is calculated according to the parameters input on commissioning (DMAX).
MWh
Amount of heat
(MWh)
HRE
Time
¼See chapter: "Setting the time", page 14.
4.1.1.
Resetting the values to zero
It is possible to reset the value to zero when the symbol T is
displayed.
1. Select a value using the ( and ) keys.
2. Press the B key for 2 seconds. The value is reset to zero.
To suspend the operation, do not press any keys for 5
seconds. The control system will automatically go back to
the value display mode.