Stopping domestic hot water production, Other settings – DE DIETRICH VIVADENS MCR-P 24_28 BIC User Manual
Page 16
4.2.5.
Stopping domestic hot water production
1. Press the N key.
The symbol N and the current temperature are displayed.
2. Press the key [-] several times until the value 0ff is displayed.
3. To confirm the new value, press the key S.
The symbol T appears.
It also possible to modify this setting using the parameter
p3
. ¼See chapter: "Other settings", page 15.
4.2.6.
Other settings
Parameter Description
Adjustment range
Factory setting
p1
Flow temperature
20 to 85 °C
75 °C
p2
Domestic hot water temperature 40 to 65 °C
60 °C
p3
Heating / DHW mode
0 = Heating deactivated (C) / DHW deactivated (T)
1
1 = Heating activated (D) / DHW activated (N)
2 = Heating activated (D) / DHW deactivated (T)
3 = Heating deactivated (C) / DHW activated (N)
p4
ECO mode
0 = Comfort mode
0
1 = Energy-saving mode
2 = Management using a programmable thermostat
p5
Anticipation resistance
0 = No anticipation resistance for the ON/OFF thermostat
0
1 = Anticipation resistance for the ON/OFF thermostat
p6
Display screen
0 = The screen stays off
2
1 = The screen stays on
2 = The screen switches off automatically after 3 minutes
("
"KK
T000142-A
4. Operating the appliance
MCR-P 24/28 BIC
15
060513 - 127686-01