Gas categories, Additional directives, Factory test – DE DIETRICH VIVADENS MCR-P 24, MCR-P .._.. MI User Manual
Page 7
1.4.2.
Gas categories
Gas category Gas type
Connection pressure (mbar) Countries
II
2H3P
Natural gas H (G20) 20
All countries except China
Propane (G31)
50
Bulgaria, Romania
37/50
Czech Republic, Spain
30
Finland, Norway, Slovenia
30/37
Greece, Italy
37
Portugal
30/50
Russia
I
2H
Natural gas H (G20) 20
China
The boiler is preset in the factory to operate on natural gas H (G20).
1.4.3.
Additional Directives
Apart from the legal provisions and Directives, the additional
Directives described in these instructions must also be observed.
For all provisions and Directives referred to in these instructions, it is
agreed that all addenda or subsequent provisions will apply at the
time of installation.
WARNING
Installation of the appliance must be done by a qualified
engineer in accordance with prevailing local and national
regulations.
1.4.4.
Factory test
Before leaving the factory, each boiler is set for optimum performance
and tested to check the following items:
4
Electrical safety
4
Adjustment (CO
2
)
4
Domestic hot water mode (Only on models with domestic hot water
production)
4
Water tightness
4
Gas tightness
4
Parameter settings
MCR-P 24 MCR-P 24/28 MI MCR-P 30/35 MI MCR-P 34/39 MI
1. Introduction
070513 - 127684-01