Gas categories, Additional directives, Factory test – DE DIETRICH VIVADENS MCR-P 24, MCR-P .._.. MI User Manual

Page 7

background image

1.4.2.

Gas categories

Gas category Gas type

Connection pressure (mbar) Countries

II

2H3P

Natural gas H (G20) 20

All countries except China

Propane (G31)

50

Bulgaria, Romania

37/50

Czech Republic, Spain

30

Finland, Norway, Slovenia

30/37

Greece, Italy

37

Portugal

30/50

Russia

I

2H

Natural gas H (G20) 20

China

The boiler is preset in the factory to operate on natural gas H (G20).

1.4.3.

Additional Directives

Apart from the legal provisions and Directives, the additional

Directives described in these instructions must also be observed.
For all provisions and Directives referred to in these instructions, it is

agreed that all addenda or subsequent provisions will apply at the

time of installation.

WARNING

Installation of the appliance must be done by a qualified

engineer in accordance with prevailing local and national

regulations.

1.4.4.

Factory test

Before leaving the factory, each boiler is set for optimum performance

and tested to check the following items:

4

Electrical safety

4

Adjustment (CO

2

)

4

Domestic hot water mode (Only on models with domestic hot water

production)

4

Water tightness

4

Gas tightness

4

Parameter settings

MCR-P 24 MCR-P 24/28 MI MCR-P 30/35 MI MCR-P 34/39 MI