Code
Description
Checking / solution
Su:10
Su:11
The BL inlet on the PCU PCB terminal
block is open
The contact connected to the BL inlet is open
4
Contact the professional who takes care of maintenance of the
appliance
Parameter error
4
Contact the professional who takes care of maintenance of the
appliance
Bad connection
4
Contact the professional who takes care of maintenance of the
appliance
Su:13
Communication error with the SCU
PCB
Bad connection
4
Contact the professional who takes care of maintenance of the
appliance
SCU PCB not installed in the boiler
4
Contact the professional who takes care of maintenance of the
appliance
Su:14
The water pressure is lower than 0,8
bar
Not enough water in the circuit
4
Top up the installation with water
Su:15
Gas pressure too low
Incorrect setting of the gas pressure switch on the SCU PCB
4
Check that the gas valve is fully opened
4
Contact the professional who takes care of maintenance of the
appliance
Su:16
The SU PCB is not recognised
Wrong SU PCB for this boiler
4
Contact the professional who takes care of maintenance of the
appliance
Su:17
The parameters saved on the PCU
PCB are impaired
Parameter error on the PCU PCB
4
Contact the professional who takes care of maintenance of the
appliance
Su:18
The PSU PCB is not recognised
Wrong PSU PCB for this boiler
4
Contact the professional who takes care of maintenance of the
appliance
Su:19
The boiler has not been configured
The PSU PCB has been changed
4
Contact the professional who takes care of maintenance of the
appliance
Su:21
Communication error between the
PCU and SU PCBs
Bad connection
4
Contact the professional who takes care of maintenance of the
appliance
Su:22
No flame during operation
No ionization current
4
Check that the gas valve is fully opened
4
Contact the professional who takes care of maintenance of the
appliance
Su:25
Internal error on the SU PCB
4
Contact the professional who takes care of maintenance of the
appliance
Su:28
An HL tank is detected whilst the boiler
cannot control it.
This message disappears after 10
seconds if the boiler can control the
HL tank
4
Wait for 10 seconds to see whether the error persists
4
Contact the professional who takes care of maintenance of the
appliance
Su:29
Communication error between the
PCU and SCU-s191 PCBs
Bad connection
4
Contact the professional who takes care of maintenance of the
appliance
Su:30
Communication error between the
SCU-s191 PCBs and the solar control
system
Bad connection
4
Contact the professional who takes care of maintenance of the
appliance
6. Troubleshooting
EGC 25
23