Code Faults
Description
Checking / solution
D03
D04
OUTL S.B FAIL.
OUTL S.C FAIL.
Circuit B flow sensor fault
Circuit C flow sensor fault
Remarks:
The circuit pump is running.
The 3-way valve motor on the circuit is no longer
powered and can be adjusted manually.
Bad connection
Sensor fault
4
Contact the professional who takes care of
maintenance of the appliance
D05
OUTSI.S.FAIL.
Outside temperature sensor fault
Remarks:
The set point of the appliance is equal to the
maximum.
The valve setting is no longer ensured but
monitoring the maximum temperature of the circuit
after the valve is ensured.
Valves may be manually operated.
Reheating the domestic hot water remains
ensured.
Bad connection
Sensor fault
4
Contact the professional who takes care of
maintenance of the appliance
D07
SYST.SENS.FAIL.
System sensor fault
Bad connection
Sensor fault
4
Contact the professional who takes care of
maintenance of the appliance
D09
DHW S.FAILURE
Domestic hot water sensor fault
Remarks:
Heating of domestic hot water is no longer
ensured.
The load pump operates.
The load temperature of the dhw tank is the same
as the boiler.
Bad connection
Sensor fault
4
Contact the professional who takes care of
maintenance of the appliance
D12
D13
ROOM S.B FAIL.
ROOM S.C FAIL.
B room temperature sensor fault
C room temperature sensor fault
Note:
The circuit concerned operates without any
influence from the room sensor.
Bad connection
Sensor fault
4
Contact the professional who takes care of
maintenance of the appliance
D14
MC COM.FAIL
Break in communication between the iSystem
module and the boiler radio module
Bad connection
4
Check the link and the connectors
Boiler module failure
4
Change the boiler module
D15
ST.TANK S.FAIL
Storage tank sensor fault
Note:
The hot water storage tank reheating operation is
no longer assured.
Bad connection
Sensor fault
4
Contact the professional who takes care of
maintenance of the appliance
D16
SWIM.P.B. S.FAIL
SWIM.P.C. S.FAIL
Swimming pool sensor fault circuit B
Swimming pool sensor fault circuit C
Note:
Pool reheating is independent of its temperature.
Bad connection
Sensor fault
4
Contact the professional who takes care of
maintenance of the appliance
D17
DHW 2 S.FAIL
Sensor fault tank 2
Bad connection
Sensor fault
4
Contact the professional who takes care of
maintenance of the appliance
D18
ST.TANK S.FAIL
Solar tank sensor fault
Bad connection
Sensor fault
4
Contact the professional who takes care of
maintenance of the appliance
D19
SOL.COL.S.FAIL
Header sensor fault
Bad connection
Sensor fault
4
Contact the professional who takes care of
maintenance of the appliance