7 technical characteristics, 1 c 310 eco – DE DIETRICH C 310 ECO - C 610 ECO User Manual
Page 16
16
C 310 ECO - C 610 ECO
02/10/07 - 300015183-001-A
7 Technical characteristics
7.1 C 310 ECO
C 310-... ECO
Unit
280
350
430
500
570
Introduction
Number of sections
5
6
7
8
9
Regulating the output
Modulating
Output (80/60°C) PN
minimum
kW
51
65
79
92
106
maximum
kW
261
327
395
462
531
Output (50/30°C) PN
minimum
kW
56
71
84
98
113
maximum
kW
282
353
427
499
573
Power input
minimum
kW
54
68
82
95
109
maximum
kW
269
336
404
471
539
Combustion gas and by-products
Gas supply pressure
mbar
17 - 25
Gas flow rate Gas H/E (15°C - 1013
mbar)
minimum
m
3
/h
5,7
7,2
8,7
10,1
11,5
maximum
m
3
/h
28,5
35,5
42,7
49,8
57,0
Gas flow rate Gas L/LL(15°C - 1013
mbar)
minimum
m
3
/h
6,6
8,4
10,1
11,7
13,4
maximum
m
3
/h
33,1
41,3
49,7
57,9
66,3
Average nitrogen oxide emission (NOx)
mg/kWh
< 60
Maximum pressure at the flue gas
nozzle
Pa
150
150
150
150
150
Combusted gas flow
minimum
Kg/h
91
114
138
160
183
maximum
Kg/h
453
565
680
793
907
Temperatures of the combusted gases
at 80/60°C
minimum
°C
57
maximum
°C
65
Boiler types:
B23, C33, C53, C63, C83
Heating
Safety temperature
°C
110
Water setting range
°C
20 - 90
Water pressure minimum
bar
0,8
Water pressure maximum
bar
6
Water content
l
49
60
71
82
93
Water resistance at
∆
T = 10°C
mmCE
4520
4400
4800
4400
5000
Water resistance at
∆
T = 20°C
mmCE
1130
1100
1200
1100
1250
Electricity characteristics
Power supply voltage
V/Hz
230 / 50
Power consumption
minimum
W
12
12
12
12
12
maximum
W
303
340
470
600
858
Insulation class
IP
21
Miscellaneous
Weight without water
kg
360
410
460
510
560
Acoustic level at 1 meter
dBA
60