Reading out measured values, Energy consumption display – DE DIETRICH ALEZIO AWHP MIV-II User Manual
Page 16
2. The symbol Q flashes.
Press the S key.
3. The information SERVICE flashes for 5 seconds.
If no buttons are pressed for 10 seconds, the screen goes back to
the main display.
To stay in the Information menu, press the S button, the
information SERVICE no longer flashes.
4. Use the - and + keys to scroll through the information.
5. Press the key > to exit the menu.
4.2.1.
Reading out measured values
Parameter Description
Unit
t1
:
4
In heating mode: Heating flow set point temperature
4
In DHW mode: DHW setpoint temperature
4
In cooling mode: Cooling setpoint temperature
4
In swimming pool mode: Pool set temperature
°C
t2
:
Measured start temperature
°C
t2
:
Domestic hot water temperature measured
°C
t2
:
Outside temperature measured
°C
lt
:
Water flow
Litres/minute
S;ft
Software version
4.2.2.
Energy consumption display
Parameter Description
Unit
c1
:
Estimated consumption of electrical energy in heating mode
(1)
kWh
c2
:
Estimated consumption of electrical energy in DHW mode
(1)
kWh
c3
:
Estimated consumption of electrical energy in cooling mode
(1)
(2)
kWh
(1) Display available if the estimated electrical energy consumption function is activated
(2) Cooling mode must be enabled
M002247-C
M002278-C
M002248-C
4. Operating the appliance
AWHP MIV-II
15
23/04/2013 - 300023321-001-03