Programming
13
AXB-TM5 Television Manager
System Send_Commands (Cont.)
Command
Description
'PTOF',
Sets the IR power-off pulse time after a power-on pulse in increments
of .10 seconds.
Syntax:
"'PTOF',
Variables:
Time = 0 through 255
Time is stored in permanent memory. System default is 15 (1.5
seconds).
Example:
SEND_COMMAND AXBTMX,"'PTOF',15"
Sets the power-off pulse time after a power-on pulse to 1.5 seconds
for the AXB-TM5.
'?PTOF'
Sends the current IR power pulse off time string ’PTOF,
Example:
SEND_COMMAND AXBTMX,'?PTOF'
Sends the current IR power pulse off time from the AXB-TM5 to the
control system in the ’PTOF
'PTON',
Sets the IR power pulse on time in increments of .10 seconds. Time is
stored in permanent memory.
Syntax:
"'PTON',
Variables:
Time = 0 through 255
System default is 5 (.5 second). ’PTON’ sets the pulse length for all
power pulses, regardless if the pulse is due to a ’PON’ or ’POF’
command.
Example:
SEND_COMMAND AXBTMX,"'PTON',20"
Sets the IR power pulse on time (delay) to 2 seconds for the
AXB-TM5.
'?PTON'
Sends the current IR power pulse on time string ’PTON,
the control system. Set the
Example:
SEND_COMMAND AXBTMX,'?PTON'
Sends the current IR power pulse on time from the AXB-TM5 to the
control system in the ’PTON
The PTOF time affects how quickly the AXB-TM5 evaluates the power state of a TV. If
a TV toggles between on and off when changing the power state, then the ’PTOF’
time should be extended. ’PTOF’ sets the time in-between each power pulse when
the AXB-TM5 is attempting to change the TV's power state (regardless if pulse if On
or Off).