Programming
9
AXB-TM5 Television Manager
Programming
You can program the AXB-TM5 to perform a wide variety of operations using Axcess
Send_Commands. This section describes channel settings, IR functions, and system
Send_Commands. Refer to the AXCESS Programming Guide for additional programming
information.
Channel Setting Commands
The AXB-TM5 use the channel setting commands listed in the following table.
Device Assignment
The device assignment must be the same as the device number set on the Device DIP switches
AXB-TM5 Channel Settings
Channel
Function
1
Generates IR/Serial functions 1, else Off
2 - 127
Channels the generate IR code for the corresponding functions
128 - 247
Push and release channels for received IR code
248
A push on this channel indicates a power failure error
249
Response LED blinks when channels 249 and 250 are On
250
Response LED lights when channel is On
251
I/O is On (switch to GND) when channel is On
252
I/O 2 is On (switch to GND) when channel is On
253
I/O 3 is On (switch to GND) when channel is On
254
I/O 4 is On (switch to GND) when channel is On
255
Channel is On if the TV Power Sensor detects a horizontal scan frequency
Turning a channel (IR/Serial function) on while another one is currently on will
automatically turn the current one off first. Contact closure inputs on I/O 1 through I/O
4 will also generate PUSHes and RELEASEs on channels 251 through 254,
respectively.