background image

113386 - 14

www.amdry.com

23

2. Technical Gas Data

a. Gas Specifications

Shaded areas are stated in metric equivalents
Abbreviations: AU (Australia) and NZ (New Zealand).

*

Manifold pressure is measured at the pressure tap on the outlet side of the gas valve when the valve is on.

**

Unregulated L.P. kit installed. Gas valve’s internal regulator (governor) is disabled.

*** Regulated L.P. installed. Gas valve’s internal regulator (governor) is adjustable.

b. Gas Connections

Inlet connection -------------- 1” N.P.T. (1” B.S.P.T. for CE and AGA dryers)
Gas Pipe supply size -------- 1-1/4” Diameter Pipe (minimum)
Heat input -------------------- 375,000 BTU/hr (94,500 kcal/hr)

1) Natural Gas

Regulation is controlled by the dryer’s gas valve’s internal regulator. Incoming supply pressure
must be consistent between a minimum of 7.0” W.C. (17.4 mb, 1.74 kPa) and a maximum of 13.0”
W.C. (32.4 mb, 3.24 kPa) pressure. Burner manifold pressure should be 3.5” W.C. (8.7 mbar, 0.87
kPa); adjust if necessary.

2) L.P. Gas (Unregulated)

Dryers made for use with unregulated L.P. gas have the gas valve’s internal pressure regulator
blocked open so that the gas pressure must be regulated upstream of the dryer. The pressure
measured at each gas valve pressure tap must be a consistent 10.5 in WC (26.1 mb, 2.61 kPa).
There is no regulator or regulation provided in an L.P. dryer. The water column pressure must be
regulated at the source (L.P. tank) or an external regulator must be added to each dryer.

3) L.P. Gas (Regulated)

Regulation is controlled by the dryer’s gas valve’s internal regulator. Incoming supply pressure
must be consistent at 11.0” W.C. (27 mbar, 2.7 kPa). Burner manifold pressure should be 8.8”
W.C. (22 mbar, 2.2 kPa); adjust if necessary.

Rating

375,000 BTU/hr

94,500 kCal/hr

395.6 MJ/hr

Manifold Pressure

*

In-Line Pressure

Orifice

Inches W.C.

mbar

kPa

Inches W.C.

mbar

kPa

Qty.

DMS

mm

Gas

Type

Natural Gas

3.5

8.7

0.87

7.0-13.0

17.4-32.4

1.74-3.24

3

#4

5.309

Natural Gas (AU / NZ)

L.P. Gas

**

10.5

26.2

2.62

11.0

27.4

2.74

3

#30

3.264

L.P. Gas (AU / NZ)

***

8.8

22.0

2.20