Starting the camera

Starting the camera

Power up

A camera power adapter for each GigE camera is available from AVT. Please con-
sult the camera technical manual for connector definition and voltage specifi-
cations

Connect to host application

Use a Category 6 or higher rated Ethernet cable to connect the camera to the
host adapter. Crossover cabling is not required, but works—the camera has cir-
cuitry to determine if a crossover cable is being used.

www

AVT Product literature

http://www.alliedvisiontec.com/us/support/downloads/
product-literature.html

Caution

For AVT Prosilica, Mako G, and Manta cameras

Use only DC power supplies with insulated cases.

Mako G, Manta, and Prosilica GT PoE models can source
power from:
– 802.3af (100 MBit/s and 1000 MBit/s), and
– 802.3at compliant PSE devices (Power Sourcing Equip-

ment): such as switches injectors or NICs

Caution

Bigeye G cameras

Operate Bigeye G cameras at 12 V (+ 5 %). The current is lim-
ited to max. 3.0 A. Operating Bigeye G cameras outside these
specifications may cause damage
.