ACT Meters GOLD-PLUS 6V/12V Battery Tester User Manual

Page 12

background image

Operating Voltage

6V and 12V DC

Reverse Polarity Protection

Red LED Indication

Max Input Voltage

15VDC

Battery Types

SLA (AGM), GEL & Flooded (WET)

Battery Sizes

6V (1.2Ah – 12Ah) and 12V (1.2Ah to 100Ah)

Ah Capacity Test

Simulated 20 hour (C20) load test to 10.50VDC

Ah Calibration

Calibrated at 0 (zero) position to brand new fully
charged premium brand SLA batteries rated at

Ah Result

Based on the battery under test temperature and
state of charge

Ah Adjustment

Provides ± Ah adjustment to brand new fully charged
standby SLA, cyclic GEL and car FLOODED lead acid
batteries

Battery Table

Recharge or replace battery when Ah capacity
available falls below 65% of the battery’s stated
capacity

Display Type

Back-lit LCD

Flat Battery Warning

6V <5.30VDC, 12V <10.50VDC

Repeat Test Operation

Can perform repeat tests continuously

DCV Accuracy

± 2% of displayed reading

Ah Accuracy

± 10% Fully charged premium brand C20hour rated
SLA batteries at 20 - 25C (68F - 77F)

Applied Pulse Load

6A 1.2Ah - 7Ah, 18A 8Ah - 100Ah

Ah Cal Adjustment

Approx ± 25 dgts

Case Construction

High impact ABS

Size

210(H) x 110(W) x 41(D)mm

EN 61326-1:2006, Class B (Emissions)

EN 55011:2007, A2 Radiated Emissions Only

EN 61326-1:2006, Basic Requirements (Immunity)

EN 61000-4-2: 1995, A1, A2

EN 61000-4-3: 2006, A1

2004/108/EC (Where Applicable)