Congratulations on purchasing the most
effective technology available today for
obtaining maximum performance & maximum
service life from your Lead-Acid batteries.
ACTIVATION MODES
6 volt: Mode 1 (Constant) active > 5.3v Mode 2 (Window) active 5.3v to 6.4v inactive > 6.4v
Mode 3 (High) Active > 6.4v
12 volt: Mode 1 (Constant) active > 10.5v Mode 2 (Window) active 10.5v to 12.8v inactive > 12.8v Mode 3 (High) active > 12.8v
24 volt: Mode 1 (Constant) active > 21.0v Mode 2 (Window) active 21.0v to 25.6v inactive > 25.6v Mode 3 (High) active > 25.6v
36 volt: Mode 1 (Constant) active > 31.5v Mode 2 (Window) active 31.5v to 38.4v inactive > 38.4v Mode 3 (High) active > 38.4v
48 volt: Mode 1 (Constant) active > 42.0v Mode 2 (Window) active 42.0v to 51.2v inactive > 51.2v Mode 3 (High) active > 51.2v
4. Troubleshooting
If FAB does not activate it may be due to one of the following or a combination:
•
Unit connected incorrectly (reverse polarity) – change the wires to the correct terminals.
•
Bad connection – clean and tighten connection terminals of FAB unit.
•
Battery has a short – have an electrician inspect the problem.
•
Battery voltage is below the activation voltage – change to mode 1 constant or recharge the battery.
•
5 amp blade fuse on positive cable is blown, open fuse holder and replace blade fuse.
5. Warning
•
FAB is supplied with wires 400mm in length. The (Black) negative wire only can be extended up
to a max. of 700mm so when the cables are spread apart they will reach terminals 1.5m apart.
•
If checking state of health of multiple individual batteries, allow a cooling down period of 30 sec
between each test to avoid damage to unit and voiding of warranty.
6. Important
•
Ampere Hours (Ah) is the rating for reserve capacity for auxiliary applications and is not to be
confused with Cold Cranking Amp (CCA) the rating for engine starting applications.
•
Although FAB will help reduce electrolyte boil-off, levels should be checked monthly.
•
Always use caution and wear protective clothing and eye protection when working with batteries.
•
Ensure unit is fi xed clear of any moving parts and wires are zip tied to avoid damage.
•
Do not use solvents to clean the unit.
7. Warranty
•
Megapulse
TM
warranty covers defects in workmanship and materials for 7 years from purchase date.
•
The warranty is not transferable and does not restart if and when a faulty unit is replaced.
•
The warranty does not cover misuse, accident, alteration or abnormal operation.
•
No warranty exists for usage outside specifi cations.
•
For warranty replacement return faulty units to a Megapulse reseller with proof of purchase.
8. For Applications Using 6v, 36v & 48 volt
•
The red LED when used on the above voltage applications indicate that the battery has the
reached 80% depth of discharge and should be recharged immediately.
6v
6v FAB
12v
12v FAB
12v
12v FAB
12v
12v
12v
24v FAB
12v
12v
12v
12v
48v FAB
6v
6v
6v
6v
24v FAB
12v
12v
12v
12v
12v FAB
12v FAB
12v FAB
2v
2v
2v
2v
2v
2v
2v
2v
2v
2v
2v
2v
+
2v
2v
2v
2v
2v
2v
2v
2v
2v
2v
2v
2v
12v FAB
12v FAB
48v
36v FAB
36v FAB
12v
12v
12v
12v
12v
12v
+
12v
12v
12v
12v
12v
12v
36v FAB
36v FAB
144v
12v
12v
12v
12v
12v
12v
12v
36v FAB
48v FAB
12v
12v
12v
12v
12v
12v
36v FAB
36v FAB
6v
6v
6v
6v
6v
6v
36v FAB
SolarMate
MAINTAINING
HEALTHY BATTERIES
Megapulse_User_Guide indd 1
27/4/11 10 59 23 AM