Installation Instructions
CMS Series Columns
5
FIXED LENGTH EXTENSION COLUMN
IMPORTANT ! : The following procedure assumes that
the ceiling plate/adapter (not included) has been properly
installed following instructions provided with ceiling plate/
adapter.
NOTE:
Intended for use with Chief accessories and mounts.
1.
Install 1-1/2" NPT threaded column (A) into plate/adapter
(See Figure 1). Securely tighten column.
•
Ensure column (A) engages four full threads into
plate/adapter.
•
Ensure cable access opening is rotated to desired
position (optional installation).
NOTE:
Cable access opening provided on columns 9" or
longer (229mm) in length. Optional installation used
when cables must exit below plate/adapter.
Figure 1
2.
Secure column (A) by tightening set screw in plate/adapter
(See Figure 1).
NOTE:
Hex key and set screw provided with plate/adapter.
WARNING:
Exceeding the weight capacity can result in
serious personal injury or damage to equipment! It is the
installer’s responsibility to make sure the combined weight of
all components attached to the CMS Series Extension
Column does not exceed 500 lbs (226 kg).
•
The weight capacity of the CMS Series Extension
Columns may be LIMITED to the lowest weight
capacity of any other component or accessory used
within the mounting system.
3.
Install and secure projector/display mount (not included) to
lower end of column (A) following instructions included with
mount.
ADJUSTABLE LENGTH EXTENSION
COLUMN
IMPORTANT ! : The following procedure assumes that
the ceiling plate/adapter (not included) has been properly
installed following instructions provided with ceiling plate/
adapter.
NOTE:
Intended for use with Chief accessories and mounts.
1.
Install 1-1/2" NPT threaded column (A or B, as applicable)
into plate/adapter (See Figure 2). Securely tighten column.
•
Ensure column (A or B, as applicable) engages four full
threads into plate/adapter.
•
Ensure cable access opening is rotated to desired
position (optional installation, column (A)).
NOTE:
Cable access opening provided on columns 9" or
longer (229mm) in length. Optional installation used
when cables must exit below plate/adapter.
Figure 2
2.
Secure column (A or B, as applicable) by tightening set
screw in plate/adapter (See Figure 2).
NOTE:
Hex key and set screw provided with plate/adapter.
3.
Install mating column (A or B, as applicable) (See Figure 2).
1
4 x
2
A
1
4 x
2
1
4 x
B
B
A
A
3
3
1
4 x