2 diameter gauge, 3 width sonar (option) – CEMB USA C71_2 evo (D) User Manual User Manual
Page 18
18
40 mm
Use and maintenance manual Rev. 10-2013
ENGLISH
INdIcATIoN
In the event of errors or faulty operation, the writing
“r.P.”:
ap
pears on the display : shift the gauge to the
rest position and repeat the calibration operation exactly
as described above. If the error persists, contact the
Technical Service Department. In the event of incorrect
input in the rim distance gauge calibration function, press
to cancel it.
6.6.2 Diameter gauge
E
Display the SETUP menu
1. Press
to view the diameter
gauge CALIBRATION function.
m
Place the round part of the gauge terminal on the
flange as shown in the figure and press
2. The number 354 ± 3° appears on the left display .
3. Turn the gauge downward position the round part
of the gauge terminal at 40 mm (radial distance)
from the flange as indicated in the figure; alternati
vely use one of the cones provided as shown in the
images
4. The number 254 ± 3° should appear on the left
display. The calibration is already correct.
If not, press the
button holding the gauge still at 40
mm: the number 254 appears on the left display.
Return the gauge to rest position.
6.6.3 Width sonar (option)
Display the SETUP menu
1. Press
to view the width sonar
CALIBRATION function.
2. Set with
the distance in mm betwe
en the Sonar sensor (0 sonar) and t
he end of the
distance gauge (at rest).
A = Distance: Gauge at rest to
0 sonar
In the event of incorrect input in the width gauge calibration
function, press
to cancel it.
Setup