18

40 mm

Use and maintenance manual Rev. 10-2013

ENGLISH

INdIcATIoN

In the event of errors or faulty operation, the writing

r.P.:

ap

pears on the display : shift the gauge to the

rest position and repeat the calibration operation exactly
as described above. If the error persists, contact the
Technical Service Department. In the event of incorrect
input in the rim distance gauge calibration function, press

to cancel it.

6.6.2 Diameter gauge

E

Display the SETUP menu

1. Press

to view the diameter

gauge CALIBRATION function.

m

Place the round part of the gauge terminal on the

flange as shown in the figure and press

2. The number 354 ± 3° appears on the left display .

3. Turn the gauge downward position the round part

of the gauge terminal at 40 mm (radial distance)

from the flange as indicated in the figure; alternati

vely use one of the cones provided as shown in the

images

4. The number 254 ± 3° should appear on the left

display. The calibration is already correct.

If not, press the

button holding the gauge still at 40

mm: the number 254 appears on the left display.
Return the gauge to rest position.

6.6.3 Width sonar (option)

Display the SETUP menu

1. Press

to view the width sonar

CALIBRATION function.

2. Set with

the distance in mm betwe

en the Sonar sensor (0 sonar) and t

he end of the

distance gauge (at rest).

A = Distance: Gauge at rest to

0 sonar

In the event of incorrect input in the width gauge calibration

function, press

to cancel it.

Setup