ACL Cathode B200 Details/Specs User Manual
Det ail s, Cathode b200, Acl inc
![background image](/manuals/322652/1/background.png)
Product
(1) For a 7 lamp transformer system refer to our T100 system. For a single lamp standard output ballast system refer to our B100 system.
(2) For multiple selections place a comma after each selection.
High Output
Double Ballast
Cold Cathode
B200
_
_
_
_
_
_
S01
(2)
DI - Dim
ND - Non Dim
S - Surface
R - Recess
Standard
Color (s)
Dim-able
Mount
Primary
Environment
120V
277V -Special
Order
Note: For a variation (custom) of this product contact ACL to request a variation number and information.
S P E C I F I C A T I O N C O D E :
DR - Dry
DP - Damp
See Chart
(1)
S01
© 20
10
Ar
chitectural Cat
hode Lighting, Inc.
Project Name
Linear Feet
Date
Architectural Cathode Lighting, Incorporated
ACL INC.
c a t h o d e l i g h t i n g . c o m
5 3 0 1 P a c i f i c B o u l e v a r d
Huntington Park California 90255 USA
Telephone 323.581.8800
Fax 323.581.7971
i n f o @ c a t h o d e l i g h t i n g . c o m
DET
AIL
S
C
ATHODE B200
A Fusion of the Art and Science of Light
C A T H O D E B 2 0 0 P R O D U C T D E T A I L S :
B200 Ballast Specifications
PRI V 120
PRI A 3.7
VA 450
SEC V 990 (1)
SEC mA 200
Watts 240 (2)
Double Lamp Ballast
(1) For 277V contact ACL.
(2) Use VA for computing loads. Use Watts for computing power consumption.
X
Y
Z
17.6”
3.776”
3.447”
output: High
date: August 21, 2008
sheet description: Remote Gang Enclosure
file: B2details.pdf
page:
1
NTS
E
A
D
C
F
B
Remote Gang Enclosure
Z
Y
X
G
A. Ballast
B. Lamp
C. Lampholder
D. Cove
E. Conduit
F. Upper Ceiling
G. Lower Ceiling