1 discharge data with constant current, continued – Alpha Technologies AlphaCell SMU-HR User Manual
Page 18
745-680-B2-002, Rev. B
18
SMU-HR 12-75
End voltage 5Min
10Min 15Min 30Min 1h
3h
5h
10h
20h
1.60V
196
136
105
77.0
49.5
23.3
14.8
7.50
3.83
1.67V
192
135
103
76.0
49.2
23.1
14.7
7.40
3.80
1.70V
192
135
103
76.0
49.2
23.0
14.6
7.40
3.78
1.75V
190
135
103
76.0
49.0
23.0
14.4
7.30
3.75
1.80V
188
135
103
75.0
47.0
22.5
14.0
7.20
3.70
1.85V
175
123
99.0
67.5
45.8
20.7
14.0
7.10
3.65
SMU-HR 12-90
End voltage 5Min
10Min 15Min 30Min 1h
3h
5h
10h
20h
1.60V
366
228
172
105
65.4
28.7
17.5
9.55
5.16
1.67V
344
216
165
100
64.5
27.6
17.2
9.46
4.98
1.70V
315
208
162
91.2
62.6
25.8
16.8
9.42
4.90
1.75V
309
202
156
86.6
59.6
24.9
16.4
9.39
4.78
1.80V
276
193
142
80.2
55.8
23.9
15.5
9.20
4.65
1.85V
244
184
128
73.9
52.0
23.1
14.5
9.07
4.52
SMU-HR 12-100
End voltage 5Min
10Min 15Min 30Min 1h
3h
5h
10h
20h
1.60V
320
218
180
114
75.0
30.0
19.1
10.0
5.25
1.67V
290
215
173
113
74.0
29.7
18.9
9.90
5.20
1.70V
280
213
172
113
73.0
29.5
18.7
9.80
5.07
1.75V
275
212
170
112
72.0
29.0
18.5
9.80
5.00
1.80V
250
208
168
110
70.0
28.5
18.3
9.70
4.85
1.85V
228
200
164
103
68.0
27.9
18.0
9.70
4.80
SMU-HR 12-150
End voltage 5Min
10Min 15Min 30Min 1h
3h
5h
10h
20h
1.60V
525
360
263
158
99.0
41.0
28.6
15.9
7.91
1.67V
473
329
255
153
98.9
40.8
28.4
15.7
7.88
1.70V
449
317
246
150
98.6
40.8
28.4
15.5
7.88
1.75V
399
293
233
147
97.5
40.5
28.2
15.3
7.84
1.80V
360
272
222
143
96.3
40.4
27.9
15.0
7.56
1.85V
273
224
192
131
95.3
40.2
27.7
14.7
7.11
5.1
Discharge Data with Constant Current, continued