3.3 Changing Oil

Drain the oil while the engine is still warm to assure rapid and complete draining.

Make sure to turn the engine switch “OFF” before draining the oil.

CAUTION!

1. Remove the side maintenance cover.
2. Remove the oil dipstick.
3. Install the oil drain pipe (included with the generator).
4. Drain the dirty oil into a container. Be sure to allow time for the oil to drain completely.
5. Refill with the recommended oil, and check to be sure the oil level is at the upper line on the dipstick.
6. Reinstall the dipstick and then the maintenance cover and tighten the screws securely.

Recommended oil is SAE 15W-40 when ambient temperature is above 32° F (0° C).

Synthetic SAE 0W-40 is recommended if operating temperatures are below 32° F (0° C).

Engine oil capacity: 15.6 fl oz (460 ml)

Recommended Oil

SAE 0W-40

SAE 10W-40

0° F

32° F

113° F

(-18° C)

(0° C)

(45° C)

3.0 Maintenance

Dispose of used motor oil in a manner that is compatible with the environment and local disposal regulations.

ATTENTION:

Figure 3-2, Temperature Range and Oil Types