BeAMS / PLK WM AsyM TID
Plank Wall Mount asyMMetric
Technical Installation Data
Install wall brackets at the desired elevation and at intervals
per Page 1. Only use screws with flat contact faces. Taper-head
screws will cause brackets to shift during installation. Bracket
elevation should be accurately controlled to ensure level rows.
#12 or #14 Screws
(Supplied by others)
Wall Bracket
Wall Bracket
Desired fixture height
#6 or #8 Screws
(supplied by others)
Wall cleat for cable option
Install J-Boxes so that the top of the openings are 3 1/4"
to 3 1/2" above the intended height of the fixture. This
will give a J-Box opening of 1 1/8" to 1 3/8" above the top
of the wall bracket/fixture.
Step 1
Step 2
Step 3
2"× 4" J-Box
(Supplied by others)
Desired Fixture Height
3 1/2"
3 1/4"
Wall Bracket
2"
1 3/8"
1 1/8"
Install optional wall cleats, if provided, using two (2) #4 screws
(supplied by others) at the height shown above and at the
intervals per Page 1.