1. Attach connector brackets to reflector on
each housing using the #8 screws. Ensure
the angles are in the same direction on each
housing. (4 total)
2. Insert Top Light Seal halfway into one of the
Housings.
3. Insert Aligner with Pem Studs into the "C"
channel slots on one of the housings (2
total)
4. Use the #8 nuts to secure the aligner to the
housing A. (2 total)
5. Attach each Light Seal to the Aligner using
the #8 nuts. Do not tighten the nut at this
point. (2 total)
6. Butt Housing B against Housing A while
engaging Top Light Seal and electrically
connecting in-row wiring.
7. Engage the connector brackets with the
screws provided. Tighten the screws until
the housings are pulled together.
8. Secure the Aligner in Housing B with #8
nuts provided and tighten.
9. Tighten the nuts on the side light shields.
CONNECTION INSTRUCTIONS
Housing A
Housing B
Aligner w/ Pem
Studs (2 places)
#8 Nuts
(6 Places)
Light Seal (2 Places)
#8 Screws (6 places)
Conn Brackets (4 Places)