1. Attach connector brackets to reflector on

each housing using the #8 screws. Ensure
the angles are in the same direction on each
housing. (4 total)

2. Insert Top Light Seal halfway into one of the

Housings.

3. Insert Aligner with Pem Studs into the "C"

channel slots on one of the housings (2
total)

4. Use the #8 nuts to secure the aligner to the

housing A. (2 total)

5. Attach each Light Seal to the Aligner using

the #8 nuts. Do not tighten the nut at this
point. (2 total)

6. Butt Housing B against Housing A while

engaging Top Light Seal and electrically
connecting in-row wiring.

7. Engage the connector brackets with the

screws provided. Tighten the screws until
the housings are pulled together.

8. Secure the Aligner in Housing B with #8

nuts provided and tighten.

9. Tighten the nuts on the side light shields.

CONNECTION INSTRUCTIONS

Housing A

Housing B

Aligner w/ Pem

Studs (2 places)

#8 Nuts

(6 Places)

Light Seal (2 Places)

#8 Screws (6 places)