3 technical data – Elmo Rietschle G-BH10 User Manual
Page 6
Technical Data
610.44431.40.000
6 / 30
© Gardner Denver Deutschland GmbH
3.1
Nominal and Limiting Values Pump
G-BH100 with enclosed motor and
integrated electronics
external electronics
2BH10 02-_AB32
2BH10 02-_AB22
2BH10 02-_AA53
Weight
1.2 kg [2.65 lbs]
1.5 kg [3.31 lbs]
Dimensions
see Fig. 1 & Fig. 2, page 8
Sound level
2
48 dB(A)
51 dB(A)
55 dB(A)
max. permissible total
differential pressure
3
at +15°C:
- vacuum pump operation
4
100 mbar
105 mbar
185 mbar
- compressor operation
5
105 mbar
105 mbar
190 mbar
max. permissible differential
pressure between pump interior
and surroundings
0.15 bar
max. permissible intake and
ambient temperature
+ 40°C [+104°F]
max. permissible speed
6
9,500
min
-1
12,000
min
-1
15,000
min
-1
bearing life L10
7
20,000
h
electrical data
see section 3.2, "Nominal and Limiting Values Motor and Electronics",
page 7, and section 5.2.1, "Electrical Connection (Motor)", page 11
Max. permissible dynamic load of the G-BH100 due to vibrations from outside:
Vibration frequency
Vibration value
< 6.3 Hz
Vibration displacement
s ≤ 0.16 mm
6.3 Hz ... 63 Hz
Vibration velocity
v
eff
≤4.5 mm/s
> 63 Hz
Vibration acceleration
a ≤ 2.55 m/s²
2
Surface sound pressure level (EN ISO 3744), measured at a distance of 1 m [3.28 ft] at an operating point of ap-
prox. 2/3 of the permissible total differential pressure with the pipes / hoses connected and without vacuum or
pressure limiting valve.
3
Permitted only with:
unobstructed cooling
,
an operating voltage of 24 V
,
a speed reference value of 10 V and
left-handed rotation of the
G-BH100.
The indicated temperature refers to the gas intake temperature. It is assumed that the gas intake tem-
perature equals the ambient temperature of the
G-BH100.
IMPORTANT: For the max. permissible total differential pressure at temperatures other than +15°C
[+59°F]see
"Fig. 3", page 9.
In case of increased throttling inside the suction or delivery pipe a pressure relief valve must be provided
.
In case of reduced speeds by means of a lower speed reference value the max. permissible total differ-
ential pressures change as well
.
4
Vacuum operation:
extraction of air
having the indicated temperature at the suction branch and a pressure of 1013 mbar
at the delivery branch
.
5
Compressor operation:
compression of air
having the indicated temperature at the suction branch and a pressure of 1013 mbar
at the delivery branch
.
6
Max. permissible speed due to the mechanical components and the design of the unit.
7
For:
operation within the permissible operating range
,
the max. permissible dynamic load due to vibrations from outside and
fastening by means of rubber / metal elements (available as accessories).
3 Technical