Technical Data

610.44431.40.000

6 / 30

© Gardner Denver Deutschland GmbH

3.1

Nominal and Limiting Values Pump

G-BH100 with enclosed motor and

integrated electronics

external electronics

2BH10 02-_AB32

2BH10 02-_AB22

2BH10 02-_AA53

Weight

1.2 kg [2.65 lbs]

1.5 kg [3.31 lbs]

Dimensions

see Fig. 1 & Fig. 2, page 8

Sound level

2

48 dB(A)

51 dB(A)

55 dB(A)

max. permissible total
differential pressure

3

at +15°C:

- vacuum pump operation

4

100 mbar

105 mbar

185 mbar

- compressor operation

5

105 mbar

105 mbar

190 mbar

max. permissible differential
pressure between pump interior
and surroundings

0.15 bar

max. permissible intake and
ambient temperature

+ 40°C [+104°F]

max. permissible speed

6

9,500

min

-1

12,000

min

-1

15,000

min

-1

bearing life L10

7

20,000

h

electrical data

see section 3.2, "Nominal and Limiting Values Motor and Electronics",
page 7, and section 5.2.1, "Electrical Connection (Motor)", page 11


Max. permissible dynamic load of the G-BH100 due to vibrations from outside:

Vibration frequency

Vibration value

< 6.3 Hz

Vibration displacement

s ≤ 0.16 mm

6.3 Hz ... 63 Hz

Vibration velocity

v

eff

≤4.5 mm/s

> 63 Hz

Vibration acceleration

a ≤ 2.55 m/s²

2

Surface sound pressure level (EN ISO 3744), measured at a distance of 1 m [3.28 ft] at an operating point of ap-

prox. 2/3 of the permissible total differential pressure with the pipes / hoses connected and without vacuum or
pressure limiting valve.

3

Permitted only with:

unobstructed cooling

,

an operating voltage of 24 V

,

a speed reference value of 10 V and

left-handed rotation of the

G-BH100.

The indicated temperature refers to the gas intake temperature. It is assumed that the gas intake tem-
perature equals the ambient temperature of the

G-BH100.

IMPORTANT: For the max. permissible total differential pressure at temperatures other than +15°C
[+59°F]see

"Fig. 3", page 9.

In case of increased throttling inside the suction or delivery pipe a pressure relief valve must be provided

.

In case of reduced speeds by means of a lower speed reference value the max. permissible total differ-
ential pressures change as well

.

4

Vacuum operation:

extraction of air

having the indicated temperature at the suction branch and a pressure of 1013 mbar
at the delivery branch

.

5

Compressor operation:

compression of air

having the indicated temperature at the suction branch and a pressure of 1013 mbar
at the delivery branch

.

6

Max. permissible speed due to the mechanical components and the design of the unit.

7

For:

operation within the permissible operating range

,

the max. permissible dynamic load due to vibrations from outside and

fastening by means of rubber / metal elements (available as accessories).

3 Technical