G-bh100 – Elmo Rietschle G-BH10 User Manual
Page 15
Installation and Commissioning
© Gardner Denver Deutschland GmbH
15 / 30
610.44431.40.000
The scope of supply of the external electronics
(Drivecontrol VT-D) includes a connector with a
300 mm wiring harness to connect the Drivecon-
trol to the supply voltage and control voltage.
In order to meet the requirements bearing on
electromagnetic compatibility a suitable EMI
filter (e.g. CORCOM, Type 6ET1, 10A) must be
connected in series with the external-electronics.
The connecting cable between the EMI filter and
the G-BH100 must have a length of at maximum
0,3 m.
5.2.1.2 G-BH100
with
integrated electronics
With this type the electronics is located inside the
motor.
i
IMPORTANT!
With the integrated-electronics type
G-BH100 the electronics is particu-
larly sensitive to overheating!
It is imperative to ensure sufficient
heat dissipation and cooling!
On delivery the integrated-electronics type G-
BH100 is not equipped with a connector at the
connecting cable. In this instance the operator
can, according to the requirements of the system,
connect a connector at his option, connect the
terminals to a terminal strip, etc.
The electrical connection is to be carried out:
according to the applicable national and local
laws and prescriptions
according to the applicable system-dependent
prescriptions and requirements
according to the applicable prescriptions of
the utility company
Via the motor connecting cable the supply volt-
age as well as the different control signals are
applied to the integrated electronics.
For the assignment of the leads or strands please
refer to Fig. 8 as well as the following table.
Lead colour
Assignment
Cable
old version
Cable
new version
pink red +V
CC
yellow black Gnd
green green n
des
white white A
grey grey B
blue blue n
Ist
brown --
not
connected
red -- not
connected
Fig. 8: Connection of the integrated electronics type
G-BH100