Installation and Commissioning

610.44431.40.000

18 / 30

© Gardner Denver Deutschland GmbH

5.3 Commissioning

WARNING!

Operation of the G-BH100 only:

 with the pump lid assembled
 with the pipes/ hoses connected to

the suction and delivery branches
or

 in case of operation with open

suction or delivery branches
(drawing-in of gases from or dis-
charge of gases into the surround-
ings)

 with a piece of pipe or hose hav-

ing a length of at least 120 mm
connected to the branch in ques-
tion

 with bearing end housing

WARNING!
Do not reach into the G-BH100
through open suction or delivery
branches!
Do not insert any objects into the G-
BH100 through the openings!

i

IMPORTANT!
The G-BH100 must not be operated
with the suction or delivery branches
sealed up or jammed!

WARNING!
Before start-up
 check pipes / hoses and vessels

for sufficient strength!

 check pipe / hose connections for

tightness!

check fasteners for secure fixing

Proceed as follows:

 Make

sure

-

that the suction and delivery pipes are cor-
rectly connected,

-

that in case of operation with open suction
or delivery branches (drawing-in of gases
from or discharge of gases into the sur-
roundings)
a piece of pipe or hose having a length of
at least 120 mm
is connected to the
branch in question in order to prevent the
impeller from being reached by fingers.

-

that the suction and delivery pipes are not
jammed,

-

that all fasteners are properly tightened,

-

that the correct voltage and current are
applied.

 Set the control voltage serving as speed ref-

erence and applied to n

des

to 0 V at first.

 Turn on the indicated operating voltage.

Now increase the control voltage serving as

speed reference and applied to n

des

(0 to

10 V) to your desired value or the value given
on the data sheet. By means of this speed
control the operating point of the G-BH100 is
adapted to the operating point of the system.

 Check the connections for tightness (ensure

that there is no fluid leakage).