beautypg.com

Elmo Rietschle G-BH10 User Manual

Page 19

background image

Operation

© Gardner Denver Deutschland GmbH

19 / 30

610.44431.40.000

WARNING!

Operation of the G-BH100 only:

 with the pump lid assembled
 with the pipes / hoses connected

to the suction and delivery bran-
ches or
in case of operation with open suc-
tion or delivery branches (drawing-
in of gases from or discharge of
gases into the surroundings) with
a piece of pipe or hose having a
length of at least 120 mm
con-
nected to the branch in question

 with the bearing end housing

i

IMPORTANT!
The G-BH100 must not be operated
with the suction or delivery branches
sealed up or jammed!

CAUTION!
Burning and scalding hazard due to
hot surfaces of the G-BH100!
Do not touch during operation!

WARNING!
Before start-up and at regular inter-
vals
 check pipes / hoses and vessels

for sufficient strength!

 check pipe / hose connections for

tightness!

 check fasteners for secure fixing


Speed control:

During operation the speed of the G-BH100 can
be modified. This allows to adapt the operating
point of the G-BH100 to changes in the operating
point of the system.
In order to do so adjust the control voltage ap-
plied to n

des

within a range of 0 to 10 V.






































































6 Operation