5.1 Mounting

General view G-BH100 (pump side)
1. Delivery branch
2. Arrows indicating delivery direction
3. Fixing lugs for fastening to a mounting surface
4. Suction branch
5. Electrical connecting cable

Fig. 4: General view G-BH100


For the arrangement of the G-BH100 and its
components see

-

Fig. 4: .


For the space required and the arrangement of
the mounting holes required for fastening the
G-BH100 to the mounting surface please refer to

-

Fig. 1: , page 8,

The G-BH100 must be mounted as follows:

-

the shaft being in any position,

-

such as not to exceed the vibration values
given in section 3, "Technical Data",

-

for heat dissipation and cooling
provide a minimum distance of 15 mm on
each side
except for the pump lid side on which a smal-
ler distance of at least 2 mm is permissible
(in case of mounting using rubber / metal
elements, see page 10).








CAUTION!
Choose the place of installation /
the mounting surface of the
G-BH100 so that there is no haz-
ard of tripping or bumping!

i

IMPORTANT!
Do not install theG-BH100 close
to heating surfaces! No direct in-
solation!

CAUTION!
Lay the electrical connecting cable
so that it might not be damaged
by outer influences and is free
from tensile stress!


Sound and vibration attenuation:

 In order to reduce sound emission fasten the

G-BH100 only to parts or components that do
not conduct or emit sound easily
(e.g. thin
walls, plates).

 Provide

sound-absorbing shims, termed

rubber / metal elements (available as acces-
sories). These are rubber pads placed be-
tween the four fixing lugs and the mounting
surface and used to absorb vibrations.

i

IMPORTANT!

During operation the surface of the
G-BH100 might have high tem-
peratures of more than 100°C!

Temperature-sensitive parts or
components, e.g. electrical wires
or cables or electronic compo-
nents must not be in contact with
or fastened to these surfaces!

CAUTION!

Burning and scalding hazard due
to hot surfaces of the G-BH100
during operation!

Provide a guard against acciden-
tal contact.


Place the rubber / metal elements (rubber pads)
between the fixing lugs (Fig. 4, # 6) and the
mounting surface.
Fasten theG-BH100 to the mounting surface via
the fixing lugs using four suitable bolts or nuts.
Property class of the bolts or nuts: 8.8 according
to ISO 898.
Secure the four fixing bolts against unintentional
loosening due to vibrations.

5 Installation and Commissioning

5

4

1

2

3