Elmo Rietschle G-BH10 User Manual
Page 10
Installation and Commissioning
610.44431.40.000
10 / 30
© Gardner Denver Deutschland GmbH
5.1 Mounting
General view G-BH100 (pump side)
1. Delivery branch
2. Arrows indicating delivery direction
3. Fixing lugs for fastening to a mounting surface
4. Suction branch
5. Electrical connecting cable
Fig. 4: General view G-BH100
For the arrangement of the G-BH100 and its
components see
-
Fig. 4: .
For the space required and the arrangement of
the mounting holes required for fastening the
G-BH100 to the mounting surface please refer to
-
Fig. 1: , page 8,
The G-BH100 must be mounted as follows:
-
the shaft being in any position,
-
such as not to exceed the vibration values
given in section 3, "Technical Data",
-
for heat dissipation and cooling
provide a minimum distance of 15 mm on
each side
except for the pump lid side on which a smal-
ler distance of at least 2 mm is permissible
(in case of mounting using rubber / metal
elements, see page 10).
CAUTION!
Choose the place of installation /
the mounting surface of the
G-BH100 so that there is no haz-
ard of tripping or bumping!
i
IMPORTANT!
Do not install theG-BH100 close
to heating surfaces! No direct in-
solation!
CAUTION!
Lay the electrical connecting cable
so that it might not be damaged
by outer influences and is free
from tensile stress!
Sound and vibration attenuation:
In order to reduce sound emission fasten the
G-BH100 only to parts or components that do
not conduct or emit sound easily (e.g. thin
walls, plates).
Provide
sound-absorbing shims, termed
rubber / metal elements (available as acces-
sories). These are rubber pads placed be-
tween the four fixing lugs and the mounting
surface and used to absorb vibrations.
i
IMPORTANT!
During operation the surface of the
G-BH100 might have high tem-
peratures of more than 100°C!
Temperature-sensitive parts or
components, e.g. electrical wires
or cables or electronic compo-
nents must not be in contact with
or fastened to these surfaces!
CAUTION!
Burning and scalding hazard due
to hot surfaces of the G-BH100
during operation!
Provide a guard against acciden-
tal contact.
Place the rubber / metal elements (rubber pads)
between the fixing lugs (Fig. 4, # 6) and the
mounting surface.
Fasten theG-BH100 to the mounting surface via
the fixing lugs using four suitable bolts or nuts.
Property class of the bolts or nuts: 8.8 according
to ISO 898.
Secure the four fixing bolts against unintentional
loosening due to vibrations.
5 Installation and Commissioning
5
4
1
2
3