Shut-Down and Longer Standstills
610.444430.40.000
22 / 32
© Gardner Denver Deutschland GmbH
9
Shut-Down and Longer
Standstills
WARNING
Improper use of the machine can result in
serious or even fatal injuries!
Have you read the safety precautions in
Chapter 1, "Safety", Pg. 3 f.?
Otherwise you may not carry out any work with
or on the machine!
9.1 Draining
DANGER
Electrical danger!
Before beginning work on the unit or system,
the following measures must be carried out:
Deenergize.
Secure against being switched on again.
Determine
whether
deenergized.
Ground and short-circuit.
Cover or block off adjacent energized parts.
WARNING
Danger due to gauge pressure and vacuum!
Danger due to escaping fluid!
Before beginning work on the unit or system:
Interrupt supply of operating liquid.
Bleed lines and vacuum pump/compressor
(depressurize).
Switch off the pump-motor unit.
The above safety precautions apply when
working on the unit or system.
Provide suitable catch containers below the
vacuum pump/compressor cover.
Open the sealing plug of the drain hole
(Fig. 3, Pg. 14, Item 5).
Allow the liquid to drain out.
Colse the sealing plug again,
tightening torque for G⅛" = 4.5 Nm ± 10 %
[3.32 ft lbs ± 10 %].
OR
Switch off the pump-motor unit.
The above safety precautions apply when
working on the unit or system.
Have a suitable catch container ready.
Disconnect the hose connections on the
inlet connection, discharge connection and
operating liquid opening.
Remov ethe mounting screws on the feet of
the pump-motor unit.
Place the pump-motor unit on the vacuum
pump/compressor cover and tilt it several
times over the connection.
Remount the mounting screws on the feet.
Reattach
the
hoses.
9.2
Preparing for longer standstill
Before a longer standstill (from approx.
4 weeks) or when there is danger of frost,
proceed as follows:
Drain pump-motor unit as described in
Chapter 9.1, "Draining", Pg. 22.
Remove the pipe/hose from the intake or
discharge connection.
Pour ¼ l [0.066 gal (US); 0.055 gal (UK)] of
preservative (rust protection oil, e.g.
Mobilarma 247 form Mobil Oil)
into the open intake or discharge
connection.
Close the intake and discharge connection,
as well as the operating-liquid port and
remount the disconnected pipes/hoses.
Guide a screwdriver through the central
opening in the fan guard up to the shaft end
on the external fan side (see Fig. 10,
Pg. 23).
Turn the shaft by hand using the
screwdriver.
Remove the screwdriver again.
You have two options for the standstill:
Either the pump-motor unit remains
connected in the system,
or the unit is removed for storage.