8 Operation

WARNING

Improper use of the machine can result in
serious or even fatal injuries!
Have you read the safety precautions in
Chapter 1, "Safety", Pg. 3 f.?
Otherwise you may not carry out any work with
or on the machine!

WARNING

Danger due to gauge pressure and vacuum!
Danger due to escaping fluid!
Danger due to rotating parts!

The pump-motor unit may only be put into
operation when the following conditions are
met:
 Fan guard and vacuum pump/compressor

cover and housing are mounted.

 The lines to the discharge connection, inlet

connection and operating-liquid port are
attached.

 The lines and connections have been

tested for strength and leaks.

CAUTION

If the unit is run dry, the mechanical seal will
be destroyed in a matter of seconds!
DO NOT switch on as long as the unit is not
filled with operating liquid!

WARNING

Danger of burns and scalding from hot
surfaces of the pump-motor unit and from
hot fluids!
Do not touch during operation!
Allow to cool after shut-down!

NOTICE

Maximum permissible quantity of water
entrained via the inlet connection:
See Fig. 9, Pg. 19.

CAUTION

The feeding in of overheated steam at the inlet
connection of the pump-motor unit while it is
not rotating has the following effect:
 Operating liquid is pressed out of the pump-

motor unit.

 Considerable thermal loading of the pump-

motor unit.

The pump-motor unit may be damaged!
Before feeding in overheated steam at the inlet
connection, switch on the pump-motor unit for
approx. 10 s to ensure sufficient supply with
operating liquid. The operating liquid cools the
pump-motor unit.



8.1 Self-priming

operation

Follow the instructions contained in
Chapter 7.2, "Self-priming operation", Pg. 17
for this operating mode.


8.2

Operation with operating-liquid feed

Start-up

For non-automatic operation (Fig. 6, Pg. 19):

 Open the stop valve (Item 4) manually.

The operating liquid is fed in.

 Switch on the unit.


For automatic operation (Fig. 7, Pg. 19):

 Switch on the unit.
 The solenoid valve (Item 4) opens

and the operating liquid is fed in.


Shut down:

For non-automatic operation (Fig. 6, Pg. 19):

 Switch off the pump-motor unit.
 Close the stop valve (Item 4) manually.

Feeding of the operating liquid is cut off.

 The following applies for the control valve

(Item 3) for setting the operating-liquid flow
rate:
In case of an interruption in operation, the
valve setting (i.e. the valve position or the
open valve cross-section) is not changed.