7.2.2 Air fi ltering

NOTICE

Insuffi cient maintenance on the air fi lter
The power of the machine lessens and damage may
occur to the machine.

Intake air fi lter:
The fi lter cartridges (Fig. 6/f

1

) must be cleaned

monthly or more often depending on the level of
contamination by purging from the inside outwards.
In spite of cleaning the fi lters their separation ef-
fi ciency will continue to deteriorate. Therefore the
fi lters should be replaced every six months.The fi lter
insert (Fig. 6/f) is removed for purging after remov-
ing the screws (Fig. 6/s

1

) on the fi lter housing cover

(Fig. 6/d) of the fi lter housing area Fig. 6/e). The fi lter
cartridges (Fig. 6/f

1

) are replaced on the fi lter base

by undoing the screws (Fig. 6/s

2

).

Also clean the fi lter housing area (Fig. 6/e) .
Re-assemble in reverse order. Use the gasketFig. 6/
c) again when installing.

Fig. 6 Air fi ltering

U

Gas ballast valve

c

Gasket

d

Filter housing cover

e

Filter housing area

f Filter

insert

f

1

Filter cartridge

s

1

Screw

s

2

Screw